7
E 14
25 W - 230 V~
T300°C
A
GB
IMPORTANT
The wires in the mains cable are coloured as follows:
GREEN AND YELLOW........EARTH
BLUE....................................NEUTRAL
BROWN...............................LIVE
REPLACING OF THE CABLE
If the cable becomes damaged or worn, replace it, observing the
following instructions:
- open the box of the supply board as shown in the diagram below;
- unscrew screw “A” that secures the cable;
-replace the cable with one of the same length and which corresponds
to the features described in the table; switch the appliance off, and
shut the gas tap;
- connect the ‘green-yellow” earth wire to the terminal “ “, leaving
it approximately 10 mm longer than the live wire;
- connect the “blue” neutral wire to the terminal marked “N”;
- connect the live wire to the terminal marked “L”.
Always isolate the cooker from the electricity supply, shut off the gas
supply temporarily and proceed as follows.
- change the injectors,
- adjust the minimum flow of the burners.
REPLACEMENT OF COOKTOP INJECTORS
To change the cooktop injectors, proceed as follows: remove the
grids, remove burners and flame-spreaders (see fig.A), change the
injector (see fig.B) and replace it with another one suitable for the
new type of gas (see table D). Re-assemble everything in reverse
order, ensuring you position the flame-spreader correctly.
This appliance must be installed by a qualified person in
accordance with the latest IEE Regulations and in compliance
with the manufacturer’s instructions.
Check that the voltage is the same as that stated on the rating plate.
The rating plate is located on the back cover.
WARNING! THIS APPLIANCE MUST BE EARTHED
If an fixed appliance is not equipped with supply cable and plug, the
power supply must be fitted with a disconnect switch in which the
distance between contacts permits total disconnection in accordance
with overvoltage category III, as required by installation regulations.
We recommend that the cooker circuit is rated to 13 amps.
Cable type HO5 RRF 3 X 1.5 mm2
Connecting the mains cable
Open the mains terminal block cover as shown, unscrew screw “A”
the cable clamp, and loosen the screws in the mains terminal block
“L N E” which secure the three
wires of the mains cable. Fit the
cable and refit screw “A”, the cable
clamp.
Allow sufficient cable length for the
cooker to be pulled out for cleaning,
but do not let it hang lower than
50mm (2”) from the floor. The cable
can be looped if necessary, but
make sure that it is not kinked or
trapped when the cooker is in
position.
A BFig. 11
MINIMUM FLOW ADJUSTMENT FOR COOKTOP TAPS
To adjust the minimum, proceed as follows: switch the burner on, and
turn the knob towards the minimum flow position . Remove the knob
from the tap, introduce a small screwdriver in to the tap rod (fig. 11).
Attention: in taps with security valve, the minimum adjustment screw
“Z” is placed outside the tap rod (fig. 12).
WARNINGS
Isolate the cooker from the electricity supply before attempting to
replace the oven lamp.
The oven lamp is of a special type designed to withstand high
temperatures. To replace it, proceed as follows: remove the protective
glass (A) and replace the burnt-out bulb with one of the same type.
Re-fit the protective glass.
DISMANTLING THE COOKTOP
If it becomes necessary to repair or replace internal components,
proceed as follows: remove the glass lid from its position by sliding
off upwards.
Remove the grids, the burners and flame-spreaders (see fig. 13),
unscrew the visible screws “V” located on the cooktop (see fig. 14).
Dismantle the cooktop by unscrewing the 4 rear screws “A” (see fig.
15 ).
Loosen the adjustment screw in order to increase the flow or tighten
it to decrease the flow.
The proper adjustment is obtained when the flame is approximately
3 or 4 mm in length.
For butane/propane gas, the adjustment screw must be fully screwed
down.
Make sure that the flame does not go out when passing quickly from
the max. flow to the minimum flow .
Assemble the knob again.

Fig. 12

Z

Values referred to Hs - 15°C - 1013,25mbar
TAB. D
Cat. II 2H3+
TABELLA GENERALE INIETTORI
Kind of gas
mbar
Nozzle
Burners
Power
KW Consum
N° max. min. max. min.
115
Rapide
3,00 0,75 286 l/h 72 l/h reg.
NATURAL 20 97
Semi rapide
1,75 0,48 167 l/h 46 l/h reg.
G 20 72
Auxiliary
1,00 0,33 95 l/h 31 l/h reg.
128
Triple crown
3,30 1,30 315 l/h 124 l/h reg.
BUTANE 28-30 85
Rapide
3,00 0,75 219 g/h 55 g/h 42
G 30 65
Semi rapide
1,75 0,48 128 g/h 35 g/h 31
50
Auxiliary
1,00 0,33 73 g/h 24 g/h 27
PROPANE 37 93
Triple crown
3,30 1,30 241 g/h 95 g/h 60
G 31
By pass
ELECTRICAL CONNECTION
GAS ADJUSTMENT
APPLIANCE MAINTENANCE