Electrical Connection

The oven is designed to be connected to 230V (50Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS OVEN MUST BE EARTHED

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For Uk use only

Connection

Min. size

Cable / flex

Fuse

via

Cable/flex

type

 

 

 

 

 

 

 

 

• 13 A socket

2.5 mm2

3 core

13 A

outlet

 

 

butyl

min.

• 13 A

 

 

insulated

 

 

spur box

 

 

 

 

 

 

 

 

 

 

 

• Cooker

2.5 mm2

PVC/PVC

13 A

Control

 

 

twin and

Circuit

 

 

earth

 

 

For Europe use only

 

 

 

 

 

 

 

Min. size Cable/flex

Cable / flex type

 

Fuse

 

 

 

 

 

1.5 mm2

 

H05 RR-F

 

13 A

 

 

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow-green earth wire at any point. The earth wire should be 2 cm longer than the live and neutral wires.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load and that the power supply is properly earthed.

Themanufacturerdisclaimsanyresponsibilityshould these safety measures not be carried out.

Live wire

Neutral wire

Earth wire

(yellow-green) at least 2 cm longer

15

Page 15
Image 15
Electrolux EOG 6000 manual Electrical Connection, This Oven Must be Earthed