17
Conversion from Natural to LPG Gas
GAS INJECTOR NOMINAL NOMINAL GAS REDUCED BY-PASS NOMINAL
TYPE MARK GAS FLOW IN GAS NEEDLE GAS
1/100 mm POWER POWER (1/100 mm) PRESSURE
(kW) m3/h g/h (kW) (mbar)
114 2,7 0,257 - 1,0 Reg. 20
78 2,5 - 182 1,0 52 28-30 / 37

Natural Gas

(G20)

LPG

(G30/G31)

IMPORTANT
The replacement/conversion from Natural to
LPG should only be undertaken by a
competent and qualified engineer.
It is important to note that this model is designed for use
with natural gas but can be converted for use with LPG
providing the correct injectors are fitted. The gas rate is
adjusted to suit.

Replacement of gas oven

burner injector

To replace the gas burner oven injector, follow this
procedure:
1. Remove the bottom plate of the oven (“A”) to access
the gas oven burner;
2. Undo the two fixing screws (“C”) which keep the gas
oven burner in place
3. Gently slide the oven gas burner off the injector
support (“D”) and slowly move it to the left hand side.
Check that the burner bush does not slip off the burner
mouthpiece, and take care not to cause stress to the
spark plug connection wire (“E”) and the thermocouple
(“F”) conductor;
3. With a 7 mm socket spanner unscrew and remove
the gas burner injector (“D”), and replace it with the
required one (see Table on this page);
4. Reassemble the burner following the same procedure
backwards.
The oven burner does not require any primary
air regulation.

Gas Oven Burner Data