Installation and Connection Instructions
45
• The wire coloured green and yellow must be connected to the termi-
nal marked with the letter “E“ or by the earth symbol or coloured
green and yellow.
• The wire coloured blue must be connected to the terminal “N“ or col-
oured black.
• The wire coloured brown must be connected to the terminal marked
“L“ or coloured red.
• Upon completion there must be no cut, or stray strands of wire
present and the cord clamp must be secure over the outer sheath.
1 WARNING! A cut off plug inserted into a 13 amp socket is a seri-
ous safety (shock) hazard. Ensure that, if it is necessary to cut off
the plug, it is disposed of safely and not retained.
Connections
The water inlet and drain hoses, as well as the mains cable must be
connected beside the dishwasher as there is insufficient space behind
the appliance.
The plumbing and electrical installation example given below can only
be regarded as a recommendation.
Two 45° or Straight Connections,
Outer ø 19mm, Length 30 mm Double tap Water drain Water inlet
Water
drain
Water
inlet
Mains
cable
Mains
cable