Electrolux FI2590FA user manual Technical data, Installation, Closing the door, Positioning

Models: FI2590FA

1 16
Download 16 pages 25.49 Kb
Page 8
Image 8
Closing the door

8electrolux

5.Install the lamp cover.

6.Tighten the screw to the lamp cover.

7.Connect the mains plug to the mains socket.

8.Open the door. Make sure that the lamp comes on.

Closing the door

1.Clean the door gaskets.

2.If necessary, adjust the door. Refer to "In- stallation".

3.If necessary, replace the defective door gaskets. Contact the Service Center.

Technical data

Dimension of the recess

Height

Technical data Width

Installation Depth

The technical information are situated in the rating plate on the internal left side of the ap- pliance and in the energy label.

1225 mm

560mm

550mm

Installation

Positioning Read the "Safety Information" carefully for your safety and correct operation of the appliance before installing the appliance.

Positioning

Install this appliance at a location where the ambient temperature corresponds to the cli- mate class indicated on the rating plate of the appliance:

Climate

 

Ambient temperature

class

 

 

SN

 

+10°C to + 32°C

N

 

+16°C to + 32°C

ST

 

+16°C to + 38°C

T

 

+16°C to + 43°C

 

 

 

Electrical connection

Before plugging in, ensure that the voltage and frequency shown on the rating plate cor- respond to your domestic power supply. The appliance must be earthed. The power supply cable plug is provided with a contact