13
Cleaning the filters
Pull the Comfort Panel to open it.
Remove the filters one by one pushing them towards
the back side of the unit and simultaneously pulling
downwards.
The metal grease filters can be washed, by hand, in mild
soapy water or in a dishwasher. Allow to dry completely
before refitting. Any kind of bending of the filters must
be avoided when washing them.
When fitting the filters into the hood pay attention that
they are mounted in correct position and that the handle
faces outwards.
Close the comfort panel.
Alarm signal reset

• Stop the motor.

• Press the F -touch control for at least 4 seconds

until the T1 -touch control flashes.

Before carrying out any maintenance or
cleaning isolate the cooker hood from the
mains supply.
Charcoal Filters
In the recirculation mode the charcoal filters absorb
smells and unwanted odours.
This charcoal filters cannot be washed or regenerated,
and must be replaced when the F touch control starts
to flash, or at least once every 4 months. The alarm is
only triggered when the motor is on.
Enabling/Disabling the alarm signal
In Recirculation Version Hoods, the Filter saturation Alarm
must be enabled at the time of installation or later.
Switch off the lights and the motor.
• Disconnect the mains power supply to the hood by
removing the motor unit power supply cable connector,
switching off the power supply at the Mains or turning
the Main switch off.
Restore the connection, pressing and holding T2.
Release the touch control, touch controls L, T2 and F
will light up normally.
Within 3 seconds press the touch control F until the
key itself flashes to confirm as follows:
• 2 flashes – Charcoal odour Filter saturation Alarm
ENABLED
• 1 f lash - Charcoal odour Filter saturation Alarm
DISABLED