Installation and connection instructions
46
Water Drainag e
The appliance drain hose should hook into a standpipe, the hook in the
drain hose is formed using the plastic “U-Piece“ supplied. The standpipe
should have an internal diameter of approximately 38 mm (see dia-
gram) thus ensuring there is an air break between the drain hose and
standpipe.
Important! It is essential to lay
the drainage hose without kinks.
When discharging into a stand-
pipe ensure that the top of the
curve in the hose end is no more
than 90 cm (35.4’’) and no less
than 60 cm (23.6’’) above floor
level.
The upright standpipe should
have a minimum, length of
30 cm (12’’) from the bottom of
the elbow to the top of the pipe
(see diagram). Make sure that it is
designed in such a way that the
end of the drain hose cannot be
covered with water.
Longer drain hoses are available
in lengths of 2.7 and 4 metres
from your AEG Service Force
Centre.