For the installer - Safety information

For the installer - Safety information

Check the appliance for transportation damage before installation.

Any electrical work required to install this appliance should be carried out by a qualified electrician or competent person.

This tumble dryer is designed to be vented through to the open air. It should have its own ventilation system which should not be joined with any other ventilation system connected to any other appliance.

The dryer must not be vented into a chimney, or flue pipe designed to carry the exhaust from a fuel burning heating appliance.

If the tumble dryer is installed next to a fuel burning stove, a heat insulation non-flammable pad must be inserted between the fuel burning stove and the tumble dryer: (dimensions 85 x 57 cm).

If the dryer is installed in a room with a fuel burning heating appli- ance, consult your local Corgi registered installer.

The tumble dryer should not be installed in situations which may be subject to freezing temperatures.

The installation site must be well ventilated.

Ensure the appliance does not stand on the electrical supply cable.

If the machine is situated on carpeted floor, please adjust the feet in order to allow air to circulate freely.

The tumble dryer must be level.

Observe the safety precautions in the operating instructions for your dryer.

Air is drawn in through vents at the rear and front of this appliance. Therefore, keep the area around the appliance clear.

7

Page 7
Image 7
Electrolux LAVATHERM 32600 installation instructions For the installer Safety information