5.CONNECTING TO GAS

This appliance is designed to be installed with an appliance flexible connection only. Supply piping should not be less than R³/8 (³/8" B.S.P.). Connection is made to the Rc½ (½" B.S.P.) female threaded entry pipe located just below the hotplate level on the rear left hand side of the appliance.

Check for gas soundness after connecting the gas supply.

The gas bayonet connector must be fitted in the shaded area indicated in Fig. 3. Take into account that it must be possible to pull the appliance forward sufficiently. The

hose must not get caught on the stability bracket.

Fig.3

All dimensions in mm

IMPORTANT: FLEXIBLE TUBING USED MUST COMPLY WITH BS. 669 CURRENT EDITION. L.P.G. FLEXIBLE CONNECTIONS MUST BE OF A TYPE SUITABLE FOR L.P.G. AND CAPABLE OF OPERATION UP TO 50MBAR AND TO CARRY A RED STRIPE, BAND OR LABEL.

NOTE: ONLY LIQUID SEALANTS CAN BE USED IN THREADED GAS CONNECTIONS. DO NOT USE P.T.F.E. TAPE.

6.FITTING THE BATTERY

1.The battery holder is located at the front left hand side of the bottom storage compartment (see Fig. 4).

2.Open bottom compartment flap to gain access to the battery holder.

3.

From inside the bottom compartment, lift the battery

Fig.4

 

holder lid and fit the 1.5 volt battery (see Fig.4)

 

 

ensuring it is fitted as indicated by the symbols on the

 

4.

battery holder.

 

After fitting battery close lid of holder.

 

7.PRESSURE TESTING

1.The oven injector is used as the pressure test point.

Remove the oven furniture. Remove oven burner box retaining clips (one spring clip from each side) and remove box front cover. Replace one clip back into the right hand side of the burner box.

Remove oven burner by removing the spring clip from the right hand side of the oven burner and slide the burner off the injector whilst easing it towards the front of the appliance, taking care not to strain the F.S.D. phial.

2.Connect the pressure gauge to the oven injector.

3.Check the supply pressure by turning the thermostat on and one hotplate tap full on and light the

appropriate burner.

The pressure should be either:

(i)

For Natural Gas

20mbar

(ii)

For LP.Gas

The pressure must be set to 28 mbar for use on butane or 37 mbar for use

 

 

on propane.

4.Turn off the taps, disconnect the pressure gauge and replace oven burner and cover, ensuring that the F.S.D. phial is correctly located into the bracket on the burner.

5.Check operation of oven.

36

Page 36
Image 36
Electrolux LYRIC50 installation instructions Connecting to GAS, Fitting the Battery, Pressure Testing

LYRIC50 specifications

The Electrolux LYRIC50 is a state-of-the-art air conditioner that embodies efficiency, design, and cutting-edge technology, making it a highly sought-after option for temperature control in homes and offices. This model not only cools or heats spaces but also enhances indoor air quality, providing comfort throughout the year.

One of the standout features of the LYRIC50 is its Smart Climate Control technology. This innovative feature allows users to adjust and monitor temperatures remotely via a smartphone application. The integration of Wi-Fi connectivity enables homeowners to manage their air conditioning system from virtually anywhere, ensuring that the home is set to a comfortable temperature upon arrival.

The LYRIC50 incorporates advanced inverter technology, which significantly increases energy efficiency. Inverter air conditioners adjust the speed of the compressor motor, allowing it to operate at various levels. This capability not only reduces electricity consumption but also provides a more consistent indoor temperature, eliminating the discomfort of temperature fluctuations associated with traditional systems.

Noise reduction is another significant characteristic of the Electrolux LYRIC50. Designed with quiet operation in mind, it features a low-noise outdoor unit that minimizes disturbance while running. This makes it an excellent choice for residential areas and places where silence is preferred, such as bedrooms or offices.

The air purifier feature included in the LYRIC50 enhances indoor air quality by filtering out dust, allergens, and harmful particles. With a multi-stage filtration system, the air conditioner ensures that the air circulating within a space is clean and healthy, which is particularly beneficial for allergy sufferers and those with respiratory issues.

Additionally, the LYRIC50 has an eco-friendly refrigerant, R32, which has a lower global warming potential compared to older refrigerants. This commitment to sustainability reflects Electrolux’s dedication to environmental responsibility while still providing high-performance air conditioning solutions.

Overall, the Electrolux LYRIC50 is more than just an air conditioning unit; it represents a fusion of design, technology, and environmental awareness. With smart connectivity, energy-efficient operation, low noise levels, and improved air quality, this air conditioner meets the demands of modern living while providing unparalleled comfort in every season.