MAKE ELECTRICAL CONNECTIONS

WARNING: Electrical wiring must be done by a qualified person(s) in accor- dance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wir- ing.

1.Remove the wiring box cover. Remove a knockout from the wiring box.

2.Secure the conduit to the wiring box through a conduit connector.

3.Make electrical connections. Connect white to white, black to black and green to green.

4.Replace wiring box cover and screws. Make sure that wires are not pinched between cover and box.

WIRING BOX

COVER

FIG.13

INSTALL DECORATIVE FLUES

1.Carefully place the decorative flue on the hood. Fig. 14.

-On ducted installation in rooms with 8-foot ceilings, the air vents are concealed. Install the flue with the air vents down.

-On non-ducted installations in rooms with 8-foot ceilings, the air vents are exposed. Install the flue with the air vents up.

-On ducted and non-ducted installations in rooms with 9-foot ceilings, the vents are exposed. Install the flue with air vents up.

ROOMS WITH 10-FOOT CEILINGS (DUCTED HOODS ONLY)

Rooms with 10-foot ceilings require flue extension model FXWC50EC available from your local dealer. Discard the upper flue supplied with the product. Replace it with the flue extension.

2.Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 15.

3.Secure the upper flue with (2) 3.9x9.5mm mounting screws. Fig. 15.

UPPER FLUE

UPPER FLUE

VENTS

VENTS EXPOSED

CONCEALED

3.9x9.5mm

MOUNTING SCREWS

UPPER

FLUE

LOWER

LOWER

FLUE

FLUE

 

FIG. 14

FIG.15