Glass & Stainless Canopy Hood
RH42PC60G S
12 1/8"
PRE-INSTALLATION CALCULATIONS
13 3/16"
S H
A
KP
Counter Height 36" standard
C
K = Kitchen height C = Counter height P = Preferred height
of hood bottom above counter (24"- 30" allowed, NOT more than 36" recommended)
A = Canopy height H = Hood height for installation
H =
S = Chimney structure height for installation
S =
35"
min.
57"
max.
Dimensions from base of hood to ceiling, and include clearance
required for28"
2 11/16"
Top
Wiring box
41 7/8"
Air outlet - 7 7/8" diam.
Controls
installation.(min. height with one
cover)
25 3/16"
42" Glass & Stainless Canopy Island Hood Specifications
•Product Weight – 87 Lbs.
•Island/Peninsula Installation
•Ventilation is convertible to be either ducted outside, or recirculated inside requiring no ducting.
•Sones Rating – 9.0
•Voltage Rating – 120V/60 Hz/15 Amps
•Connected Load (kW Rating) @120 Volts = 0.516 kW (For use on adequately wired 120V, dedicated circuit having
•Amps @120 Volts = 4.16 Amps
•Always consult local and/or national electric codes. Check local building codes for installation requirements, as they may vary per locale.
•Minimum installation height allowed from bottom of hood to cooking surface is 24" - 30" for electric and 30" for gas. (NOT more than 36" recommended.)
•To prepare mounting surface, adequate structure and support must be provided, capable of supporting 150 lbs.
Ducted Option Specifications
•For outside ventilation only.
•Exhaust Duct Required – 8" round
•For most efficient airflow exhaust, use a straight run or as few elbows as possible.
•Use metallic flex ducting only to connect rigid duct directly to transitions (if allowed by code).
•Thermal breaks such as short section of nonmetallic duct, should be used in areas of extreme cold.
•Cold weather installations should have additional backdraft damper installed.
•Refer to web for detailed duct preparation installation instructions.
Ductless (Recirculated) Option Specifications
•If ducting to outside is not an option, vent hood can be converted to ductless with use of optional
•Refer to web for detailed convertible ventilation installation instructions.
Pre-Installation Calculations
•Select hood preference height (P) that is comfortable for user (24" - 30" minimum allowed, NOT more than 36" recommended).
•Calculate hood height (H) for installation (H =
•Confirm that (H) is within minimum to maximum range for hood. If not, adjust installation.
•Calculate chimney structure height (S). Use formulas, check dimensions of hood. Save calculation for use later in installation.
Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
•
USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • | High standards of quality at Electrolux Major Appliances mean we are | |
constantly working to improve our products. We reserve the right to change | ||
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • | ||
specifications or discontinue models without notice. |
RH42PC60G 02/08 | © 2008 Electrolux Major Appliances, NA | Printed in the U.S.A. |