TECHNICAL DATA

 

 

 

 

DIMENSIONS

 

 

 

 

 

 

Height

 

Width

Depth

Height to hotplate

900mm (nominal)

550mm (nominal)

600mm

 

 

 

 

 

(to front of

 

 

 

 

 

door panel)

Space for fixing at hotplate level

2mm minimum clearance

 

 

 

Space for fixing above hotplate level

Flush-see important note 'Location of Appliance' page 43

Minimum space above hotplate

787mm (If a cooker hood is fitted refer to the cooker hood

 

installation instructions).

 

 

 

Weight of appliance

60.5kg.

 

 

 

 

Minimum distance from rear wall

5mm (spacer given by pressed spacer on vent panel).

CONNECTIONS

 

 

 

 

 

Gas

Rear left hand side of cooker at

hotplate level.

 

 

Rc½ (½" B.S.P. female).

 

 

 

Electric

220V/240V 50 Hz mains 3 core cable is supplied with an integral,

 

moulded plug fitted with a 3 amp fuse.

 

IGNITION

 

 

 

 

 

Spark generator

APCO 6+1 MG 7424/1

 

 

 

GRILL

Natural Gas

 

 

L.P.Gas

 

Heat Input

3.3kW (11263 Btu/h)

 

3.0kW (215 g/h)

 

Injector Marking

138

 

 

088

 

HOTPLATE

 

 

Natural Gas

 

 

R.H.F.

R.H.R.

 

L.H.R.

L.H.F

Heat Input

1.0kW

2.0kW

 

2.0kW

2.8kW

 

(3412 Btu/h)

(6824 Btu/h)

(6824 Btu/h)

(9554 Btu/h)

Injector Marking

079

104

 

104

130

 

 

L.P.Gas

 

 

R.H.F.

R.H.R.

 

L.H.R.

L.H.F.

Heat Input

1.0kW

2.0kW

 

2.0kW

2.7kW

 

(71.85 g/h)

(143.7 g/h)

(143.7 g/h)

(194 g/h)

Injector Marking

051

072

 

072

083

41

Page 41
Image 41
Electrolux SIG 400 installation instructions Technical Data