Fitting the Hob into the worktop
Carry out the building in of the hob as follows:
Φ• put the seals supplied with the hob, on the edges of the cut out: place them exactly on the front and rear edge and at 50 mm. from the side edges, taking care that the seals meet without overlapping;
•place the hob in the cut out, taking care that it is centred;
•fix the hob with the relevant fixing clamps and screws, as shown in the diagram. When the
screws have been tightened, the excess seal | FO 0199 |
can be removed.
The edge of the hob forms a double seal which prevents the ingress of liquids.
Electrical connections
Seal
Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability should these safety measures not be observed.
This hob is designed to be connected to a
Before switching on, make sure the electricity supply voltage is the same as that indicated on the hob rating plate. The rating plate is located on the bottom of the hob. A copy is attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cord incorporating a 3amp plug fitted. In the event of having to change the fuse, a 3amp ASTA approved (BS 1362) fuse must be used.
Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code:
Green and Yellow - Earth
Blue- Neutral
Brown- Live
Φ— Connect the green and yellow (earth) wire to the terminal in the plug which is marked with
the letter 'E' or the earth symbolor coloured green and yellow.
—Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter 'N' or coloured black.
—Connect the brown (live) wire to the terminal in the plug which is marked with the letter 'L' or coloured red.
Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.
A cut off plug inserted into a 13 amp socket is a seriuos safety (shock) hazard. Ensure that the cut off plug is disposed of safely.
Permanent Connection
In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.
The switch must not break the yellow and green earth cable at any point.
Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg. C.
FO 0390
12