14
To Fit the Ducting
1. Fit the ducting spigot and blanking plate, by
aligning the interlocking lugs on the fittings,
with the recesses in the aperture.
2. Insert and turn anti-clockwise to lock the spigot
and blanking plate into position.
3. Remove the charcoal filter and ensure the
slider control is in the ducting position.
To Remove the Charcoal Filter
1. Open the visor and remove the metal inlet
grille.
2. Carefully remove the screw from the centre of
the charcoal filter while holding the filter
securely.
3. The charcoal filter can now be removed.
Recirculation
The charcoal filter must be fitted for
recirculation and the slider control must be in
the recirculation position.
Wall Cabinet Fitting
Before fitting the cooker hood beneath any
type of wall cabinet ensure it is firmly fixed to
the wall in accordance with the manufacturer’s
instructions.
1. Use the paper template provided to mark the
hole positions on the underside of the cabinet.
Ensure the front edge of the template is
aligned with the front edge of the cabinet
carcase.
2. Check the distances are correct with a tape
measure as stated on the template. The four
holes are 5mm (
1
/
4
”) diameter.
3. If the ducting spigot is being used cut a
circular hole using a pad saw or similar cutter.