Electrolux Z7040 Display, Filtration Stages, For Best Results, Filter Cleaning Intervals

Models: Z7040

1 8
Download 8 pages 12.97 Kb
Page 4
Image 4
DISPLAY

DISPLAY

AB

E

F

G

C

D

ARoom noise level indicator (when in audio position).

BHigh level of contamination. Set to (3) or auto.

CMedium level of contamination. Set to (2) or auto.

DLower level of contamination. Set to (1) or leave at this setting.

EIndicates time to clean filters according to schedule.

FIndicates filter must be changed.

GFan speed indicator.

FILTRATION STAGES

To ensure the highest quality of air, the air cleaner has a specially designed triple stage filtration system. When air enters the unit, it passes through three filters and is then let out into the room again.

Stage 1 Two pre-filters remove large particles such as strands of hair.

Stage 2 The electrostatic main filter (Reference No. EF100) removes smaller particles such as pollen, mildew spores, dust.

Stage 3 Carbon filter, (Reference No. EF101). The carbon filter reduces the amount of gases and odor (for example, tobacco smoke) from the indoor air. (The carbon filter will reduce the air flow slightly.) The unit can be run without the carbon filter.

CAUTION: High voltage. Turn off the power switch and unplug before servicing. This equipment should be inspected frequently and collected dirt removed from it regularly to prevent excessive accumulation that may result in flashover and/or risk of fire.

FOR BEST RESULTS

Place the air cleaner on the floor next to a wall. The air cleaner draws in air at floor level and blows it out at the top. Place the air cleaner along the same wall as the room heater so that the rising warm air coincides with the air flow of the cleaner. When using two or more units in one room, place them along the same wall, as far apart as possible.

CAUTION: Do not place under a smoke detector. The cleaned air may delay the smoke detector operation in the event of a fire.

FILTER CLEANING INTERVALS

Depending on the level of air contamination, we recommend that you follow the cleaning procedure every two months or when the indicator on the display lights up.

The main filter may need cleaning more frequently if dust is visible on the upper filter surface.

Replace the main filter once a year or more frequently if necessary or when the indicator on the display lights up.

When using the carbon filter, replace every three to six months or sooner if you are no longer able to detect a reduction in odors.

4