Modelling Light
The touch pad (14) controls the modelling lamp on/off and the proportional light.
Select the power with the touch pad (15). The modelling light output (100%) is achieved when the power value is set to maximum.
Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the light output is proportional to the selected flash power.
For all types of Style RX compact flash units, use maximum 250 - 300W modelling lamps.
230V Modelling lamps and fuses |
|
|
|
| |
Unit | Modelling lamp | Code | Socket | Fuse | Code |
Style 300RX | 250W halostar | 23018 | E27 | 2,5AF | 19033 |
Style 600RX | 250W halostar | 23018 | E27 | 2,5AF | 19033 |
Style 1200RX | 300W halogen | 23022 | GX 6,35 | 2,5AF | 19033 |
|
|
|
|
| |
120V Modelling lamps and fuses |
|
|
|
| |
Unit | Modelling lamp | Code | Socket | Fuse | Code |
Style 300RX | 150W halogen | 23037 | BA15D | 4 AF | 19035 |
Style 600RX | 150W halogen | 23037 | BA15D | 4 AF | 19035 |
Style 1200RX | 250W halogen | 23038 | BA15D | 4 AF | 19035 |
|
|
| |||
120V «Canada Version» Modelling lamps and fuses |
|
| |||
Unit | Modelling lamp | Code | Socket | Fuse | Code |
Style 300RX | 150W halogen | 23012 | E27 | 4 AF | 19035 |
Style 600RX | 150W halogen | 23012 | E27 | 4 AF | 19035 |
Style 1200RX | 150W halogen | 23012 | E27 | 4 AF | 19035 |
|
|
|
| ||
230V Modelling lamp options: |
| 120V Modelling lamp: |
|
23022 | 23101 | 23018 | 23037 |
This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp 300W, GX 6.35 (code 23022) for Style 300 and 600 RX units.
If the modelling lamp does not light up.
1.The filament is broken after long use (replace lamp and fuse)
2.The filament is broken after shock (replace lamp and fuse)
3.An internal component failure (return the unit to customer service)
8