Modelling Light

The touch pad (14) controls the modelling lamp on/off and the proportional light.

Select the power with the touch pad (15). The modelling light output (100%) is achieved when the power value is set to maximum.

Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the light output is proportional to the selected flash power.

For all types of Style RX compact flash units, use maximum 250 - 300W modelling lamps.

230V Modelling lamps and fuses

 

 

 

 

Unit

Modelling lamp

Code

Socket

Fuse

Code

Style 300RX

250W halostar

23018

E27

2,5AF

19033

Style 600RX

250W halostar

23018

E27

2,5AF

19033

Style 1200RX

300W halogen

23022

GX 6,35

2,5AF

19033

 

 

 

 

 

120V Modelling lamps and fuses

 

 

 

 

Unit

Modelling lamp

Code

Socket

Fuse

Code

Style 300RX

150W halogen

23037

BA15D

4 AF

19035

Style 600RX

150W halogen

23037

BA15D

4 AF

19035

Style 1200RX

250W halogen

23038

BA15D

4 AF

19035

 

 

 

120V «Canada Version» Modelling lamps and fuses

 

 

Unit

Modelling lamp

Code

Socket

Fuse

Code

Style 300RX

150W halogen

23012

E27

4 AF

19035

Style 600RX

150W halogen

23012

E27

4 AF

19035

Style 1200RX

150W halogen

23012

E27

4 AF

19035

 

 

 

 

230V Modelling lamp options:

 

120V Modelling lamp:

 

23022

23101

23018

23037

This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp 300W, GX 6.35 (code 23022) for Style 300 and 600 RX units.

If the modelling lamp does not light up.

1.The filament is broken after long use (replace lamp and fuse)

2.The filament is broken after shock (replace lamp and fuse)

3.An internal component failure (return the unit to customer service)

8

Page 9
Image 9
Elinchrom RX 1200, RX 600, RX 300 manual Modelling Light, 230V Modelling lamps and fuses, 120V Modelling lamps and fuses