Design Guide & Applications Manual

9. EMC Considerations

For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies

RADIATED NOISE

Radiated noise may be either electric field or magnetic field. Magnetic radiation is caused by high di/dt and is generally what is measured by FCC, VDE or MIL-STD-461. Vicor converters utilize zero-current-switching, with the advantage over PWM non-zero-current-switching being that zero-current-switching topologies contain minimal discontinuities in the switched current waveforms, resulting in lower di/dt’s. Electric field radiation (caused by dv/dt) is “near-field,” i.e., it decays rapidly as a function of distance and as a result does not typically affect radiated measurements.

Radiation can be minimized by proper board layout. Keep all leads with AC current short, twisted or routed as overlapping planes to minimize loop cross-sectional area.

Also keep in mind the effects of capacitive coupling — even when not expected. Do not put an unshielded filter on the opposite side of the PCB from the module. Conducted noise can be capacitively coupled around the filter. Do not route input and output leads in the same cable bundle. Again, no special precautions, just good design practice.

NOISE CONSIDERATIONS

All switchmode power supplies generate a certain amount of “noise”, yet it remains one of the least understood parameters in power conversion.

VI-200s and VI-J00s both use the same topology, so their operation is very similar. These products are zero-current- switching converters — i.e., the current is zero when the main switch is turned on or off. While the switch is on, the current through the switch or the primary of the transformer is a half-wave rectified sine wave. Similar in operation to a resonant converter, these products are commonly referred to as quasi-resonant converters. The LC resonant frequency is fixed so the on-time of the switch is about 500 ns. When the switch turns on, energy builds up in the leakage inductance of the transformer (L) and then “transferred” into the capacitor on the secondary side of the module. (C, Figure 9–6) The energy processed in each pulse is fixed, and is ultimately the energy stored in this capacitor, 1/2 CV2. Since the energy in every pulse is fixed, the repetition rate of the pulse train is varied as a function of load to regulate the output voltage. Maximum repetition rate occurs at minimum line, full load and is approximately twice the LC time period or 1 µs. If the load drops by 50%, then the repetition rate is approximately one-half of maximum (since the energy in every pulse is fixed). Therefore the pulse repetition rate varies linearly with load, to a first order approximation.

 

Vs

 

L

+IN

+ OUT

 

C

Vp

Ip

 

–OUT

–IN

 

Figure 9–6— Basic zero-current-switching converter topology (VI-200 / VI-J00)

Since the energy in every pulse is related to the square of the applied voltage (CV2), the pulse repetition rate varies as approximately the square of the line voltage. For example, a 300 V input unit can vary from 200 – 400 V, or a factor of two, therefore it follows that the repetition rate must vary by approximately a factor of four to regulate the output. As previously established, the current in the primary is a half-wave rectified sine wave, but the voltage on the primary is a square wave. Since this voltage is a square wave, it contains harmonics of the fundamental switching frequency. It also includes frequencies, that extend to 70 MHz.

These frequencies can be of interest in the following circumstances. Rapidly changing voltages (high dv/dt) can generate E-fields (primarily near-field) which do not usually cause system noise problems since they significantly decrease as a function of distance. For this reason, E-fields are not measured by agencies such as the FCC or VDE. These agencies do, however, measure the magnetic radiation caused by high frequency currents in a conductor. The half-wave rectified sine wave in the transformer is an example of this, but since there are minimal discontinuities in the current waveform and the loop cross-sectional area is very small, the resultant E-field is very small. E-fields can be a problem if sensitive circuitry is located near the module. In this case, a shield can be positioned under the label side of the module as a discrete element or as a ground plane on the PCB. The other effect that occurs as a result of the 50 – 70 MHz component on the main switch is common-mode noise. (Figure 9–7)

 

Parasitic

 

Capacitance

FET

Rectifier

Shield

Shield

Ceramic

Ceramic

Baseplate

Figure 9–7— The shield layer serves to reduce the capacitance

vicorpower.com

800-735-6200

Applications Engineering 1-800-927-9474

Rev. 2.1

Page 23 of 88

Page 6
Image 6
EMC VI-200, VI-J00 specifications Radiated Noise, Noise Considerations

VI-J00, VI-200 specifications

EMC VI-J00 and VI-200 are advanced storage solutions designed to meet the diverse needs of modern enterprises. As part of the EMC product line, these models offer features intended to enhance data management, security, and scalability, making them suitable for various applications, from small businesses to large-scale data centers.

The EMC VI-J00 is renowned for its compact design and energy efficiency. It is particularly well-suited for edge computing applications, where space is limited and power consumption is a critical concern. This model leverages cutting-edge data reduction technologies such as deduplication and compression, allowing organizations to maximize storage efficiency while minimizing costs. The VI-J00 also supports multiple access protocols including NAS and block, enabling seamless integration into existing IT environments.

In contrast, the EMC VI-200 offers a more robust and scalable solution for larger enterprises requiring extensive data throughput and storage capacity. It features high-performance storage capabilities with support for NVMe technology, which significantly enhances data access speeds. The VI-200 is built with a modular architecture, allowing organizations to scale their systems as needed, adding capacity or performance without disrupting ongoing operations.

Both models incorporate advanced data protection technologies, including snapshot capabilities and remote replication, ensuring that data is secure and recoverable in the event of a failure. Additionally, they support advanced analytics and management tools that provide real-time insights into storage performance and utilization, leading to improved resource allocation.

Interoperability is another key characteristic of both the VI-J00 and VI-200. These systems are designed to work seamlessly with a wide range of applications and platforms, providing flexibility and choice for IT administrators. Their compatibility with various virtualization platforms further enhances their appeal, allowing businesses to create dynamic, efficient storage environments.

In summary, EMC VI-J00 and VI-200 are powerful storage solutions tailored to meet the demands of today's data-centric organizations. With features focused on efficiency, scalability, and data protection, they stand out as reliable options for businesses looking to optimize their data storage strategies while leveraging the latest technologies.