8 TROUBLESHOOTING

CONTINUED FROM PAGE 7

 

 

 

 

 

Symptom

 

Possible Cause

 

Corrective Action

 

 

 

 

 

 

 

 

Furnace/Air Conditioner Cycles Too Fast or

 

1.

The location of the thermostat and/or the

 

Digital thermostats normally provide precise

Too Slow (narrow or wide temperature swing)

 

 

size of the Heating/Cooling System may be

 

temperature control and may cycle faster than

 

 

 

influencing the cycle rate.

 

some older mechanical models. A faster cycle

 

 

 

 

 

rate means the unit turns on and off more

 

 

 

 

 

frequently but runs for a shorter time so there is

 

 

 

 

 

no increase in energy use. If you would like to

 

 

 

 

 

increase the cycle time, refer to step 3 on the

 

 

 

 

 

Configuration Menu

 

 

 

 

 

 

Thermostat Setting and Thermostat

 

1.

Thermostat thermometer setting requires

 

The thermometer can be adjusted +/- 3 degrees.

Thermometer Disagree

 

 

adjustment.

 

See Temperature Display Adjustment in the

 

 

 

 

 

Operation section.

 

 

 

 

 

 

Blank Display and/or Keypad Not

 

1.

Voltage spike or static discharge.

 

Use the Reset Operation listed above.

Responding

 

 

 

 

 

 

 

 

 

 

 

Heat Setpoint Will Not Respond

 

1.

The desired setpoint conflicts with the

 

Change system mode to COOL. Raise the Cool

to the Temperature Up Key

 

 

setpoint of the COOL mode.

 

setpoint. Return to HEAT mode and set desired

 

 

 

 

 

temperature.

 

 

 

 

 

 

Cool Setpoint Will Not Respond

 

1.

The desired setpoint conflicts with the

 

Change system mode to HEAT. Lower the Heat

to the Temperature Down Key

 

 

setpoint of the HEAT mode.

 

setpoint. Return to COOL mode and set desired

 

 

 

 

 

temperature.

 

 

 

 

 

 