Liebert has re- invented the

LIEBERT NPOWER3-PHASEUPS: 30-130KVA, 60 HZ, 208 OR 480VAC

double-conversion UPS. The Npower is the result of an international design collaboration and more than a decade of advanced research.

Every aspect of the Npower shows careful design and attention to detail. The rugged powertrain and advanced ActiveStar™ controls were subjected to computer simulations and thermal analysis to ensure reliable performance in every environment.

Even the physical packaging is uniquely efficient, to make fully configured systems more compact than other products on the market.

Best of all, it’s a Liebert product— designed to give the same million- hour critical bus MTBF as its older brothers.

Unmatched heritage of reliability and availability

Smallest system footprint

Excellent efficiency with non- linear loads and partial loads

Outstanding dynamic response

All-digital ActiveStar™ controls and graphical user interface

General Specifications

INPUT

Voltage

208 or 480VAC, 60 Hz

3-phase, 3- or 4-wire plus ground

 

Voltage Range

+10, -15%

(no battery discharge at -20%)

 

Frequency Range

60 Hz, ±5

Current Distortion

10% maximum reflected THD at full load with

optional input filter; 30% THD without filter

 

Current Limit

115% of full load input current

Current Walk-in

20 seconds to full load

Power Factor

0.80 lagging minimum at full load; up to 0.96

lagging at full load with optional input filter

 

Surge Protection

Sustains input surges without damage, per

criteria listed in ANSI C62.41-1980 (IEEE 587)

 

ENVIRONMENTAL

 

Operating

UPS: 32° to 104°F (0-40°C)

Temperature

Battery: 68° to 86°F (20-30°C)

Non-Operating Temp.

-4° to 158°F (-20° to 70°C)

Relative Humidity

0-95% non-condensing

Operating Altitude

Up to 6600 ft. (2000m) without derating

Acoustical Noise

Less than 65 dBA typical, measured

3.3 ft. (1m) from the unit

 

OUTPUT

 

Voltage

208 or 480VAC

3-phase, 4-wire plus ground

 

Voltage Adjustment

±5%

Range

 

Voltage Regulation

±0.5% for balanced load

±1.0% for 100% unbalanced load

 

Dynamic Regulation

±5% deviation for 100% load step

±1% for loss or return of AC input

Transient Response

Recover to ±1% of steady state within 1 cycle

Time

 

Voltage Distortion

For linear loads, 1% THD; less than 2.5% THD

for 100% nonlinear loads w/o kVA/kW derating

 

Phasing Balance

120° ±0.5° for balanced load.

120° ±1° for 100% unbalanced load

 

Frequency

±0.1%

Regulation

 

Load Power

1.0 to 0.7 lagging without derating

Factor Range

 

Overload

125% of full load for 10 minutes

150% for 1 minute w/ true sinusoidal waveform

 

STANDARDS

ETL listed to UL 1778 UPS standards and CSA certified. Meets current requirements for safe high performance UPS operation.

Npower Matching Battery Cabinet

 

Run Time (minutes) for kVA:

Dimensions

Weight

Model

30

40

50

65

80

100

130

WxDxH, in. (mm)

lb. (kg)

1FJ

12

7

-

-

-

-

-

 

1,600 (725)

1HJ

21

14

10

7

5

-

-

25x32.5x71

1,800 (815)

1LJ

28

20

14

8

5

-

-

2,350 (1,065)

(635x825x1800)

1MJ

36

25

18

12

8

5

-

2,350 (1,065)

 

1PJ

53

38

28

20

15

10

-

 

3,000 (1,360)

1PJ(130)

-

-

-

-

-

-

7

 

3,350 (1,520)

1RJ

62

45

34

25

19

13

9

49x32.5x71

3,700 (1,680)

1UJ

72

52

39

30

23

17

12

(1250x825x1800)

4,000 (1,815)

1WJ

104

74

55

40

33

25

16

 

5,050 (2,290)

2PJ

126

83

67

50

38

28

-

(2) 25x32.5x71

6,000 (2,720)

635x825x1800)

 

 

 

 

 

 

 

 

 

2PJ(130)

-

-

-

-

-

-

20

 

6,700 (3,040)

2RJ

144

104

76

55

45

35

25

(2) 49x32.5x71

7,400 (3,360)

2UJ

156

111

90

67

52

40

30

(1250x825x1800)

8,000 (3,630)

2WJ

-

-

-

97

74

55

40

 

10,100 (4,580)

3PJ

204

145

108

78

63

48

-

(3) 25x32.5x71

9,000 (4,080)

635x825x1800)

 

 

 

 

 

 

 

 

 

3PJ(130)

-

-

-

-

-

-

35

 

10,050 (4,560)

3RJ

223

161

129

94

72

54

39

(3) 49x32.5x71

11,100 (5,040)

3UJ

265

187

142

105

81

65

48

(1250x825x1800)

12,000 (5,445)

3WJ

421

302

217

157

124

94

69

 

15,150 (6,870)

4PJ

301

206

154

111

90

68

-

(4) 25x32.5x71

12,000 (5,440)

(635x825x1800)

 

 

 

 

 

 

 

 

 

4PJ(130)

-

-

-

-

-

-

50

 

13,400 (6,080)

4RJ

329

224

182

134

102

77

55

(4) 49x32.5x71

14,800 (6,720)

4UJ

377

266

201

147

111

91

67

1250x825x1800

16,000 (7,260)

4WJ

480

423

320

222

180

135

97

 

20,200 (9,160)

Maintenance Bypass Cabinets

 

Dimensions

Weight, lb. (kg) for kVA:

Model

WxDxH, in. (mm)

30-50

65-80

100-130

L or N

25x32.5x71

660 (299)

750 (340)

800 (363)

(635x825x1800)

 

 

 

 

P or Q

31.7x32.5x71

1,210 (549)

1,320 (599)

1,540 (699)

(805x825x1800)

 

 

 

 

Slim-Line Distribution Cabinet

 

Dimensions

Weight

kVA

WxDxH, in. (mm)

lb. (kg)

All

10x32.5x71

250 (113)

(254x825x1800)

 

 

Page 1
Image 1
Emerson 30-130KVA specifications General Specifications, Npower Matching Battery Cabinet, Maintenance Bypass Cabinets

30-130KVA specifications

The Emerson 30-130KVA is a cutting-edge power solution designed to meet the demands of various industries, ensuring reliability and efficiency. This range of uninterruptible power supply (UPS) systems is engineered to provide consistent power protection for critical applications, proving essential for businesses that cannot afford downtime.

One of the standout features of the Emerson 30-130KVA UPS is its modular design, allowing for scalability and flexibility. This characteristic makes it suitable for organizations that anticipate growth or have fluctuating power needs. By enabling easy addition or removal of power modules, users can tailor the system to their specific requirements without substantial investment or downtime.

The UPS technology incorporates advanced double-conversion topology. This design enhances power quality by continuously converting incoming alternating current (AC) to direct current (DC) and then back to AC. As a result, the system ensures that connected devices receive clean and stable power, protecting sensitive equipment from voltage fluctuations, surges, and interruptions.

Moreover, the Emerson UPS systems feature high-efficiency modes that help reduce energy consumption. By operating in eco-mode during non-critical loads, users can achieve significant cost savings while maintaining necessary power protection. This energy efficiency is further enhanced by the incorporation of advanced power factor correction technologies, ensuring optimal performance while minimizing energy waste.

The Emerson 30-130KVA series is equipped with a user-friendly graphical interface that simplifies monitoring and management. This intuitive display allows operators to access vital information about system performance, battery status, and operational metrics at a glance. Additionally, remote monitoring capabilities ensure that users can keep track of their UPS systems from anywhere, enhancing responsiveness to potential issues.

Safety is a paramount concern in power solutions, and Emerson meets this challenge through several built-in protection mechanisms. Features such as thermal management ensure that the UPS operates within safe temperature ranges, thereby extending the lifespan of critical components.

In conclusion, the Emerson 30-130KVA UPS represents an ideal power solution for businesses seeking reliability, efficiency, and scalability. With its modular design, advanced double-conversion technology, energy-saving modes, and user-friendly interface, it stands out as an essential tool for safeguarding critical operations against power-related disruptions. Organizations investing in this UPS will benefit from enhanced operational continuity, making it a worthwhile addition to their infrastructure.