4 MOUNTING AND WIRING
CONTINUED FROM SECOND PAGE
THERMOSTAT
C‡ B O | Y | G | W | RC RH |
C‡ B O
NOTE
For
|
|
| JUMPER |
| |
|
|
| WIRE |
| |
Y | G | W | RC RH | THERMOSTAT | |
SYSTEM | |||||
|
|
|
| ||
| Fan | Heating |
|
| |
| Relay | System |
| Hot | |
|
|
|
| ||
|
|
| 24 VAC | 120 VAC | |
|
|
|
| Neutral | |
|
|
| TRANSFORMER |
|
|
|
|
|
|
Cooling |
| Fan |
| Heating | |
System |
| Relay |
| System | |
|
|
|
|
|
|
|
|
| SYSTEM | |||||
|
|
| ||||||
|
|
|
|
|
|
|
| Hot |
|
|
|
|
|
|
|
| |
24 VAC |
|
|
|
|
|
| 120 VAC | |
|
|
|
|
|
|
|
| Neutral |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
HEATING
TRANSFORMER
24 VAC |
|
|
|
| Hot |
|
|
|
| 120 VAC | |
|
|
|
|
| Neutral |
|
|
|
|
| |
|
|
|
|
|
|
COOLING TRANSFORMER
Figure 2. Typical wiring diagram for
heat only, 3-wire, single transformer systems
|
|
|
|
| JUMPER |
| |
|
|
|
|
| WIRE |
| |
C‡ | B | O | Y | G W | RC RH | THERMOSTAT | |
SYSTEM | |||||||
|
|
|
|
|
| ||
|
|
| Cooling | Fan |
|
| |
|
|
| System | Relay |
| Hot | |
|
|
|
|
| 24 VAC | 120 VAC | |
|
|
|
|
|
| Neutral | |
|
|
|
|
| TRANSFORMER |
Figure 3. Typical wiring diagram for
cool only, 3-wire, single transformer systems
| NOTE |
|
| |
RED jumper wire (provided with thermostat) must be |
| |||
connected between thermostat RH and RC terminals | JUMPER | |||
for proper thermostat operation with this system. | ||||
WIRE | ||||
|
|
| ||
|
|
| THERMOSTAT |
C‡ | B | O | Y | G | W | RC RH | SYSTEM |
|
|
|
|
|
|
| |
|
|
| Cooling | Fan | Heating |
|
|
|
|
| System | Relay | System |
| Hot |
|
|
|
|
|
| 24 VAC | 120 VAC |
|
|
|
|
|
|
| Neutral |
|
|
|
|
|
| TRANSFORMER |
Figure 4. Typical wiring diagram for
heat/cool, 4-wire, single transformer systems
‡The 24 Volt neutral connection to terminal C on the thermostat is not required if the batteries are replaced once a year with fresh “AA” Energizer® alkaline batteries.
Figure 5. Typical wiring diagram for
heat/cool, 5-wire, two-transformer systems
JUMPER JUMPER
WIREWIRE
C‡ B O | Y | G W | RC RH | THERMOSTAT | |
SYSTEM | |||||
|
|
|
| ||
Reversing | Compressor | Fan |
|
| |
Valve* | Contactor | Relay |
| Hot | |
|
|
| 24 VAC | 120 VAC | |
* Reversing valve is energized when the |
| Neutral | |||
system switch is in the COOL position | TRANSFORMER | ||||
|
|
|
Figure 6. Typical wiring diagram for heat pump
with reversing valve energized in COOL
JUMPER JUMPER
WIREWIRE
C‡ | B O | Y | G W | RC RH | THERMOSTAT | |
SYSTEM | ||||||
|
|
|
|
| ||
| Reversing Compressor | Fan |
|
| ||
| Valve* | Contactor | Relay |
| Hot | |
|
|
|
| 24 VAC | 120 VAC | |
| * Reversing valve is energized when the |
| Neutral | |||
| system switch is in the HEAT position | TRANSFORMER | ||||
|
|
|
|