Electrical Requirements

!Manual background WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

M5 x 6 WASHER

HEAD SCREW (3)

SWITCH HOUSING

ASSEMBLY

SWITCH HOUSING

CONNECTOR

LATCH Manual backgroundManual background

MOTOR CONNECTOR

FAN BLADE Manual background

BLADE FLANGE

Figure 5

9.Turn the fan assembly upside down in preparation for mounting the fan blade assemblies. Remove and discard shipping retainers securing the motor hub in the motor housing.

NOTE: Take care not to scratch fan housing when installing blades.

10. Loosely attach one blade assembly to the motor hub using two M6 x 14 captive screws with lock- washers (Figure 6). Make sure the screws are NOT tightened. Repeat this procedure for the other four blade assemblies.

11. The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the captive screws. If one of the flanges does not seat properly on the motor hub, loosen the adjacent captive screws, re-engage and reseat the flanges, then tighten the screws again.

Figure 7

MOUNTING SCREW

NOTE: Do not pinch wires between the switch housing assembly and the switch housing plate.

14.You have now completed the assembly of your new ceiling fan. You can now proceed with hang- ing and wiring your fan.

MOUNTING SCREW

SWITCH HOUSING

ASSEMBLY

 

Figure 8

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

MOTOR HUB

M6 x 14 CAPTIVE SCREW WITH LOCKWASHER

Figure 6

SWITCH HOUSING

PLATE

FLANGE BLADE

!Manual background WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with out- let box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds.

If your fan is to replace an existing ceiling light fixture,

12.Engage the connector of the switch housing assembly with the motor connector (Figure 7). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connector latch closes properly.

13.Remove the three mounting screws from the switch housing plate (Figure 7). Position the switch housing assembly on the switch housing plate and secure using the three mounting screws (Figure 8).

turn electricity off at the main fuse box at this time and remove the existing light fixture.

!Manual background WARNING

To avoid fire or shock, follow all wiring instructions carefully.

Any electrical work not described in these instructions should be done or approved by a licensed electrician.