BLACK AND BLUE

NOTE: CEILING COVER

SUPPLY

OMITTED FOR CLARITY.

GROUNDGROUND

FAN WIRES

 

WIREWIRE

 

 

LISTED

 

WHITE SUPPLY

WIRE

 

CONNECTOR (3)

 

(NEUTRAL)

GREEN WIRE

 

 

(GROUND) FROM

 

WHITE FAN

HANGER BRACKET

 

WIRE

 

GREEN WIRE

BLACK SUPPLY

 

(GROUND) FROM

(HOT)

Figure 12

HANGER BALL

 

! WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

3.Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket.

4.Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 13).

5.Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 13.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.

CEILING COVER

THREADED STUD LOCKWASHERS (2) KNURLED KNOB

Figure 13

!WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

6.Cut the 3-speed switch pull chain to a desired length (optional). Connect the wood pendant (supplied) to the 3-speed switch pull chain by sliding the wooden pendant (small hole first) onto the pull chain. Attach the chain coupler to the end of the chain and allow the wooden pendant to fall down over the coupling.

Using Your Ceiling Fan

1.Restore electrical power to the outlet box by turning the electricity on at the main fuse box.

2.Check the operation of the fan by gently pulling on the pull chain switch.

3.All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward. If airflow is desired in opposite direc- tion, turn your fan OFF and wait for the blades to stop turning, then slide the reversing switch to the “up” position, and turn fan on again.

4.The fan blades will turn in the opposite direction and reverse the airflow.

Your fan model is equipped with a 4-position, 3-speed pull chain switch. The operating sequence is as follows:

Three-Speed

1st Pull—HIGH

2nd Pull—Medium

3rd Pull—Low

REVERSIBLE

SWITCH PULL

 

 

SPEED CONTROL

 

SWITCH

CHAIN

4th Pull—OFF

 

 

 

 

Reverse Switch Information

Season

Rotation Direction

Switch Position

Summer

Counter-Clockwise

Down

Winter

Clockwise

Up

7

U.L. Model No.: CF716

Page 7
Image 7
Emerson CF716PW00, CF716GBZ00 Using Your Ceiling Fan, Three-Speed, Reverse Switch Information, Season Rotation Direction