Electrical Requirements

! WARNING

To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

10.Engage the connector of the switch housing assembly with the motor connector (Figure 7). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the con- nector latch closes properly.

3/16-24 x 1/4" SLOTTED PHILLIP HEAD SCREW (3)

Manual background BLADE WASHER (3)

BLADE FLANGE

FAN BLADE

Figure 5

8.Turn the fan assembly upside down in preparation for mounting the fan blade assemblies.

NOTE: Take care not to scratch fan housing when installing blades.

SWITCH

HOUSING

ASSEMBLY

Figure 7

SWITCH HOUSING

CONNECTOR

MOTOR CONNECTOR

9.Rotate the motor hub until the flange screw hole is visible through the slot in the switch housing plate. Attach the blade assembly to the motor hub using two 1/4-20 x 1/2” Phillips oval head flange screws. Make sure the screws are tightened securely (Figure 6). Repeat this procedure for the other four blade assemblies.

1/4-20 x 1/2" FLANGE SCREWS (2) (INSTALL THROUGH SLOT IN SWITCH HOUSING PLATE)

SWITCH HOUSING

PLATE

BLADE FLANGE

 

Figure 6

MOTOR HUB

11.Remove the three switch housing screws from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three screws (Figure 8).

NOTE: Do not pinch wires between the switch housing assembly and the switch housing plate.

12.You have now completed the assembly of your new ceiling fan. You can now proceed with hang- ing and wiring your fan.

 

SWITCH

MOUNTING

HOUSING

SCREWS (3)

ASSEMBLY

Figure 8

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

5

The outlet box must be securely anchored and capa- ble of withstanding a load of at least 50 pounds.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

To avoid fire or shock, follow all wiring instructions carefully.

Any electrical work not described in these instructions should be done or approved by a licensed electrician.