CAUT I ON

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THIS PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

The lightning flash with arrow- head symbol, within an equi- lateral triangle is intended to alert the user to the presence of uninsulated ‘dangerous voltage’ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

CAUT I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER ( O R B A C K ) , N O U S E R SERVICEABLE PARTS INSIDE R E F E R S E R V I C I N G T O Q U A L I F I E D S E R V I C E PERSONNEL.

!

The exclamation point within an equilateral triangle is in- tended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompany- ing the appliance.

The Caution Marking maybe located at the bottom enclosure of the apparatus.

IMPORTANT SAFETY INSTRUCTIONS

1.) Read these instructions. Keep these instructions. Follow all instructions. Heed all warnings.

2.) Do not use this apparatus near water.

3.) Clean only with dry cloth.

4.) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

5.) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

6.) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

7.) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

8.) Only use attachments / accessories specified by the manufacturer.

9.) Unplug this apparatus during lightning storms or when unused for long periods of time.

10.) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

11.) This appliance shall not be exposed to dripping or splashing water and no object filled with liquids such as vases shall be placed on the apparatus.

12.) Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution

when moving the cart/apparatus combination to avoid injury from tip-over.

13.) Do not overload wall outlet. Use only power source as indicated. 14.) Use replacement parts as specified by the manufacturer.

15.) The product may be mounted to a wall only if recommended by the manufacturer.

16.) Upon completion of any service or repairs to this product, ask the service technician to perform safety checks.

1

CKS3015_010406.p65

1

4/1/2006, 16:34

Page 2
Image 2
Emerson CKS3015 owner manual Important Safety Instructions

CKS3015 specifications

The Emerson CKS3015 is a highly regarded temperature control and monitoring device designed for precise applications in various industrial settings. This unit is recognized for its robust construction, advanced technology, and user-friendly features that enhance operational efficiency.

At the heart of the CKS3015 is its state-of-the-art PID (Proportional-Integral-Derivative) algorithm, which ensures accurate temperature control by continuously measuring the temperature of the process and adjusting the output according to the difference between the desired setpoint and the actual temperature. This feature not only enhances stability but also minimizes overshoot and undershoot, making it ideal for critical temperature-sensitive operations.

The CKS3015 boasts a wide temperature range, making it versatile for various applications, from food processing to pharmaceuticals. It can operate in extreme environmental conditions, which contributes to its reliability and longevity in industrial applications. The device supports multiple thermocouple types, RTD, and analog inputs, allowing for flexibility in measurement and compatibility with different sensors.

User-friendly design is another significant characteristic of the Emerson CKS3015. It features a large, bright LCD display that provides clear visibility of temperature readings and system status. Additionally, intuitive navigation through the menu allows users to easily access and modify settings, calibrate the system, and review historical data logs.

Connectivity is a key aspect of the CKS3015, as it comes equipped with various communication interfaces, including RS-232 and Ethernet options. This allows for seamless integration into existing control systems and enhanced data management capabilities. Operators can monitor multiple devices remotely, enabling greater oversight and quicker response times to any anomalies in the process.

Moreover, the Emerson CKS3015 is designed with safety and compliance in mind. It includes features such as alarm outputs, fail-safe settings, and enhanced protection against over-temperature situations. These built-in safety mechanisms ensure the integrity of the process and help prevent equipment damage while adhering to industry regulations.

In conclusion, the Emerson CKS3015 is an exceptional choice for industries requiring precise temperature control and monitoring. Its advanced PID control, versatility in temperature range, user-friendly interface, robust connectivity options, and reliable safety features make it a top contender in the field of industrial temperature controllers. Whether for food processing, pharmaceuticals, or other critical applications, the CKS3015 delivers performance and reliability that professionals can depend on.