Infrared Remote Control for EC2
Operating Instructions
GB
The EC2 series of electronic controls can be easily and quickly programmed by means of the remote control unit using single keypad operations.
Until now, in fact, programming the
Changing the value of a parameter requires a special procedure (see 'ENABLE' button). Further safety is also provided by the 'H2' parameter that allows you to protect your system from unwilling or unauthorised access or modification of all set data.
Technical specifications |
|
Power supply | 2 x 1.5V alkaline batteries (type |
| IEC R03) Batteries are supplied. |
Case | plastic |
Dimensions | 60x160x18mm |
Storage | |
Operating temperature | 0/50°C |
Transmission | Infrared |
Weight | 80 g (without batteries) |
REMOTE CONTROL UNIT: KEYPAD
On the basis of the function performed, the buttons on the remote control unit have been grouped as follows:
•Buttons to activate / deactivate the use of the remote control unit
•
•Buttons for the remote control of the EC2 keypad
BUTTONS USED TO ACTIVATE/DEACTIVATE THE USE OF THE REMOTE CONTROL UNIT
The buttons shown on the left are the remote control unit ON/OFF buttons. They also allow you to memorize any new parameter value.
Note: A red LED indicator will be displayed on the front panel of the controller to acknowledge that a signal is being received from the IR handset.
ENABLE (blue zone) | enables the use of the remote control unit; |
| |
PRG (blue zone) | 1) ends | the programming procedure | and |
| memorizes the new values given to the | ||
| parameters; |
| |
| 2) silences the buzzer when programming the IR | ||
| controller | via remote control unit; |
|
ESC (orange zone) | interrupts the transmission without memorizing the | ||
| modifications; |
| |
0 … 9 BUTTONS: | allow you to select the access code. We advise | ||
| you to give each controller a specific access code, | ||
| especially when your control panel includes | ||
| several IR instruments or when all of them | are | |
| exposed to the beam of the remote control unit. In |
this way you will be able to modify exactly the parameters you want to change, without interfering with the data of the other controllers.
(See also 'How to use the remote control unit' and 'How to select the password').
BUTTONS USED TO MODIFY THE MAIN PARAMETERS (DIRECTLY ACCESSIBLE BUTTONS)
The most frequent parameters are directly indicated on the remote control unit. They are grouped in three zones:
• temperature parameters (grey zone);
• defrost parameters (white zone);
• superheat parameters (grey zone).
For the correct use of the buttons see 'How to use the remote control unit' next page.
BUTTONS FOR THE REMOTE CONTROL OF
THE EC2 CONTROLLER
The green zone of the remote control unit reproduces exactly the keypad of the EC2 instruments and allows you to perform the same operations, as if you were directly acting on the keypad.
Here are the main functions of the buttons:
SEL displays the value of the selected parameter
1) goes to the next parameter
2)increases the displayed data (parameters selection phase)
Service | Service (grey) sends the Neuron ID |
1) goes to the previous parameter
2)decreases the displayed value (parameters selection phase)
For the correct use of the buttons see 'How to use the remote control unit' next page.
Replacement for Rev.:00 | 1 / 4 | 20.07.2007 |