MULTIPORT ELECTRONIC CONTROLLER continued...
5.Mount encoder torque plate (21) to optical encoder (20) using screws (22) with the open slot opposite to the encoder ribbon cable.
6.Insert the shaft of optical encoder (20) into the top end of shaft (6). Align and engage the guide pin (16) into the slot of the encoder torque plate (21). Tighten setscrew (8) and capscrews (13) to secure the optical encoder (20) and the lower bracket (12) in position.
NOTE: The optical encoder (20) is adjusted and tested 100% by Sherrex Systems Ltd.
7.For MEC using AC supply voltage, install transformer (27) on the upper bracket (23) using screws (28).
8.Attach MK 3/6 terminal strip (25) to the upper bracket (23) using screws (26). Label the terminals with terminal numbers (33) 1 - 6.
9.Install fuse holder (36) and fuse (37) on the upper bracket (23).
10.Loosely attach upper bracket (23) assembly to the lower bracket (12) using screws (24).
11.Mount
NOTE: | The |
| Sherrex Systems Ltd. All units supplied by Sherrex have been 100% tested at |
| factory. |
| See the typical |
CAUTION: | Insert the encoder ribbon cable connector to |
| the male tab oriented downward to engage with the female slot in the |
| mating socket. |
12.Prepare and stamp nameplate (4) to install on top of cover (2) using drive screws (5).
13.Install ground terminal (32), ring terminal (34) and screw (35).
14.Lube and install
15.Lubricate and install
L.OPTIONAL MEC SOFTWARE PROGRAM
The MEC software program requires a minimum 486 DX33 running Windows 3.1 or Windows 95, with 4Mb of ram and 2Mb of hard disk space.
To install the program place disk 1 into the computer's disk drive. Enter Windows and click on the Run option. Type in a:\setup (or b:\setup) to launch the MEC setup program. Follow the on- screen instructions to install the program to a subdirectory and create a program group and icon.
12