5 CONTROL

Operating Instructions

5 CONTROL

See fig. 5 on page 25

Do not close all vents simultaneously as this may result in the motor/fan overheating.

The product is designed solely for cleaning air indoors and must not be used for any other purpose.

The user is liable for damages resulting from improper use. Do not use the air cleaner when parts or safety devices are faulty, absent or damaged.

The air cleaner can be controlled in three different ways:

AUsing the panel button (>> button), for selecting fan speed or AUTO mode

BUsing the remote control

CUsing the Auto Clean mode (AUTO mode)

5.1Controlling with the panel button

See fig. 2 on page 25

The panel button (>> button) allows you to control the fan speed as follows:

With the air cleaner OFF:

Press the panel button (>>); control goes to AUTO.

Press the panel button (>>); fan speed goes to •••• (TURBO).

Press the panel button (>>); fan speed goes to ••• (HIGH).

Press the panel button (>>); fan speed goes to •• (MEDIUM).

Press the panel button (>>); fan speed goes to • (LOW).

Press the panel button (>>); fan speed goes to STANDBY.

Press the panel button (>>); fan speed switches OFF.

If you keep pressing on the panel button (>>), the control will go one step every second.

5.2Remote Control operation

See fig. 3 on page 25

Remote Control Fan Speed Indicators:

LOW

••MEDIUM

••• HIGH

•••• TURBO

Note: When the motor is turned ON, from STANDBY, the air cleaner will start automatically on TURBO for 1.5 seconds. Subsequently it will switch to the last fan speed selected.

OFF: switches off air cleaner.

V and W : fan speed goes one level higher (V) or lower (W).

AUTO: switches the air cleaner to automatic operation.

5.3Automatic operation (AUTO mode)

See fig. 4 on page 25

Press AUTO on the remote control.

There is a 5 minute warm up time for the Air Quality Analyzer. It is recommended the air cleaner be plugged in continuously to avoid the warm-up delay. If you activate AUTO during this time, the led on the control panel will flash. After 5 minutes you will hear a beep and the air cleaner will operate automatically.

6 PROGRAM SETTINGS

The air cleaner is shipped with factory default program settings. The following program settings allow you to customize the air cleaner operation for your personal preference.

Program Setting 1: Service Indicator

Program Setting 2: Resetting the Service Indicator

PROGRAM: press this button once to get in the program mode. While in the program mode if no key is pressed for 60 seconds the air cleaner will return to the last setting without saving any changes.

6.1Program Setting 1: Service Indicator

The Service Indicator is used to predict when the filter will need cleaning (electronic air cleaners) or replacement (media air cleaners).

The Service Indicator automatically calculates the service interval based on the pollution level selected and the fan speed. When the filter becomes clogged the leds • and •••• will flash

each time the air cleaner is turned on.

Pollution level guidelines for establishing setting:

• LOW DUTY: general pollution without tobacco smoke

••MEDIUM DUTY: moderate tobacco smoke concentrations

••• HEAVY DUTY: high tobacco smoke concentrations

•••• EXTREME DUTY: extremely high tobacco smoke concentrations

To select the pollution level:

Press PROGRAM; you are in the program mode 1 and STANDBY led will flash once every two seconds.

Default: OFF (all leds off).

Press V: led • (LOW) will light up, meaning you've set the pollution level to LOW DUTY.

Press V: led •• (MEDIUM) will light up, meaning you have set the pollution level to MEDIUM DUTY.

Press V: led ••• (HIGH) will light up, meaning you have set the pollution level to HEAVY DUTY.

Press V: led •••• (TURBO) will light up, meaning you have set the pollution level to EXTREME DUTY.

If you want to go back to one of the previous pollution levels, press W.

Press PROGRAM to confirm setting 1 and to go to setting 2.

6.2Program Setting 2: Resetting the Service Indicator

The indicator needs to be reset when the media filter is changed out. If led • and led •••• are flashing, it is time to change the

filter(s) and to reset the indicator.

To Reset:

Press PROGRAM: you are in the program mode 2 and the STANDBY led will flash twice every two seconds.

Default: OFF (all leds are off).

If the indicator is programmed (setting 1), you will see all the leds switched on in setting 2, provided the Service Indicator is in use for a while.

Reset Service Indicator: press OFF (all leds are off).

Press PROGRAM: all user settings are saved and the air cleaner is back in normal control.