Technical Repair Guide

WARNING: RISK OF ELECTRIC SHOCK

These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

This guide contains service checks to assist service personnel in locating and correcting any condition that might occur to render the air cleaner ineffective or inoperative. The air cleaner has been designed with replaceable components, such as the high voltage power supply which allows the service person to simply replace a component rather than attempt repair of components in the field.

8ADJUSTING TO SPECIFIC ROOM CONDITIONS

Program Setting 1: Service Indicator

The Service Indicator is used to predict when the filter will need cleaning (electronic air cleaners) or replacement (media air cleaners).

The Service Indicator automatically calculates the service interval based on the pollution level selected and the fan speed. If the filter becomes clogged the led • and •••• will flash each

time the air cleaner is turned on.

Pollution level guidelines for establishing setting:

• LOW DUTY: general pollution without tobacco smoke

••MEDIUM DUTY: moderate tobacco smoke concentrations

••• HEAVY DUTY: high tobacco smoke concentrations

•••• EXTREME DUTY: extremely high tobacco smoke concentrations

Program Setting 2: Resetting the Service Indicator

The indicator needs to be reset when the media filter is changed out. If led • and led •••• are flashing, it is time to change the

filter(s) and to reset the indicator.

To Reset:

Press PROGRAM: you are in the program mode 2 and the STANDBY led will flash twice every two seconds.

Default: OFF (all leds are off).

If the indicator is programmed (setting 1), you will see all the leds switched on in setting 2, provided the Service Indicator is in use for a while.

Reset Service Indicator: press OFF (all leds are off).

Press PROGRAM: all user settings are saved and the air cleaner is back in normal control.

Program Setting 3: Maximum fan speed for Air Quality Analyzer (AUTO mode)

It is not possible to go directly to setting 3.

If the panel button (>>) and then the PROGRAM key are pressed simultaneously before confirming setting 2, you're in setting 3 and STANDBY led will flash three times every two seconds.

Adjusting the maximum fan speed for the Air Quality Analyzer is very convenient for meeting rooms and open plan offices.

Default: •••• (TURBO).

Press W and so on to go to the desired maximum fan speed.

Press PROGRAM: confirm setting 3 and go to setting 4.

To select the pollution level:

Press PROGRAM; you are in the program mode 1 and STANDBY led will flash once every two seconds.

Default: OFF (all leds off).

Press V: led • (LOW) will light up, meaning you've set the pollution level to LOW DUTY.

Press V: led •• (MEDIUM) will light up, meaning you have set the pollution level to MEDIUM DUTY.

Press V: led ••• (HIGH) will light up, meaning you have set the pollution level to HEAVY DUTY.

Press V: led •••• (TURBO) will light up, meaning you have set the pollution level to EXTREME DUTY.

If you want to go back to one of the previous pollution levels, press W.

Press PROGRAM to confirm setting 1 and to go to setting 2.

Program Setting 4: Manual lock

In setting 4 STANDBY led will flash four times every two seconds. Blocking the panel button (>>), to ensure that non-authorised people cannot control the air cleaner.

Default: unlock; no leds are burning.

Press W or V: lock; led • (LOW) is burning.

Press W or V: unlock; led • (LOW) is off.

Press PROGRAM: confirm setting 4 and go to setting 5.

Program Setting 5: Voltage output for maximum efficiency (Electronic Air Cleaners only)

In setting 5 STANDBY led will flash five times every two seconds. This setting can be used to lower the efficiency (up to 10% at low HV). This will increase the time between cleaning intervals.

Default: high HV level (7600 V); leds •, •• and ••• are burning.

0508082120/101203/C

Page 7

Owner’s manual

Page 8
Image 8
Emerson MCS600B, MCD1200W Technical Repair Guide, Adjusting to Specific Room Conditions, Program Setting 4 Manual lock