PN 51A-499AOZ/rev.H September 2010

Model 499A OZ

Ozone Sensor

For additional information, please visit our website

at www.emersonprocess.com/raihome/liquid/.

Model 499A OZ CAUTION

SENSOR/PROCESS APPLICATION COMPATIBILITY

The wetted sensor materials may not be compatible with process composition and operating conditions. Application compatibility is entirely the responsibility of the user.

Ozone Sensor CAUTION

Do not exceed pressure and temperature specifications. Pressure: 65 psig max (549 kPa abs max) Temperature: 32 to 122°F (0 to 50°C)

SPECIFICATIONS - SENSOR

Pressure: 0 to 65 psig (101 to 549 kPa abs)

Temperature: 32 to 122°F (0 to 50°C)

Process Connection: 1 inch MNPT

Wetted Parts: Polysulfone, Viton1, Teflon2 TFE, silicone

Cathode: gold

1Viton is a registered trademark of E.I. duPont de Nemours & Co.

2 Teflon is a registered trademark of E.I. duPont de Nemours & Co.

SPECIFICATIONS - FLOW CELLS

Type

PN

Wetted Materials

Process Connection

Maximum Temperature

Maximum Pressure

 

 

 

 

 

 

1-1/2 in. tee

23567-00

CPVC, Buna N

1-1/2 in. socket

122°F (50°C)

65 psig (549 kPa abs)

 

 

 

 

 

 

 

915240-03

 

3/4 in. NFPT

 

 

 

 

 

 

 

 

2 in. tee

915240-04

PVC, Buna N

1 in. NFPT

120°F (49°C)

60 psig (515 kPa abs)

 

 

 

 

 

 

 

915240-05

 

1-1/2 in. NFPT

 

 

 

 

 

 

 

 

Low Flow*

24091-00

Polyester/polycarbonate,

Compression fitting for

158°F (70°C)

90 psig (722 kPa abs)

 

 

316SS, silicone

1/4 in. OD tubing

 

 

 

 

 

 

 

 

* Pressure and temperature specifications for the low flow cell exceed the temperature and pressure specifications for the sensor.