Table | Module Power Specifications (continued) |
| |
|
|
|
|
| 155 Watts | 520.0 BTU/HR | |
|
|
|
|
| 155 Watts | 520.0 BTU/HR | |
|
| ||
Table | Redundancy Configurations for AC Line | ||
|
|
| |
No. of Power Supplies | Maximum Redundant System Load1 | Redundancy Configuration | |
| 2 | 1160 Watts | 1 + 1 |
|
|
|
|
| 3 | 2320 Watts | N + 1 |
1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.
Table A-5 Redundancy Configurations for AC Line 200—240 Vac
No. of Power Supplies | Maximum Redundant System Load1 | Redundancy Configuration |
2 | 1500 Watts | 1 + 1 |
|
|
|
3 | 3000 Watts | N + 1 |
1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.
Matrix X4‐C twist lock power cord options are as follows:
Table A-6 Twist Lock Power Cord Options
Enterasys Part Number | Twist Lock Plug Type | Power Requirement | Receptacle Type |
|
|
|
|
NEMA | 110V 20A | NEMA | |
|
|
|
|
NEMA | 220V 15A | NEMA | |
|
|
|
|
10-Gigabit Ethernet Transceiver Specifications (XFP)
The 10‐Gigabit XFP (10‐Gigabit Small Form Factor Pluggable) interface port slots on Matrix X Router IOMs can support various optional 10‐Gigabit Ethernet (10 GbE) standard type fiber‐optic modules. As of the printing of this guide, 10GBASE‐LR, ‐ER, ‐ZR, and ‐SR types are available. Table A‐7 through Table A‐9 provide specifications for each module.
Table
Item | Specification |
|
|
|
| ||
Two slots support a full 10 Gbps using LR, ER, ZR, and SR compliant | |||
| XFPs. |
|
|
|
|
|
|
Physical Dimensions | 8.5 H x 18.35 | W x 78.0 | L (mm) |
| 0.34 H x 0.72 | W x 3.07 | L (in.) |
Approximate Weight | Net: 0.34 gm (1.2 oz) |
| |
|
| ||
Operating Temperature | 5° to 40° C (41° to 104° F) | ||
Storage Temperature | |||
Operating Relative Humidity | 5% to 90% | ||
|
|
|
|
Matrix