Power Supply Requirements, Specifications, and Twist Lock Options

Table A-1 Matrix X4-C Specifications (continued)

Item

Specification

 

 

Fan Tray

 

 

 

Dimensions

4.13 cm H x 12.7 cm W x 56.52 cm D

 

1.625 in. H x 5.0 in. W x 22.25 in. D

Weight

3.31 kg (7.3 lb)

MTBF (Predicted)

381,219 hours

 

 

Environmental

 

 

 

Operating Temperature

5°C to 40°C (41°F to 104 °F)

Storage Temperature

-30°C to 73°C (-22°F to 164°F)

Operating Relative Humidity

5% to 95% (non-condensing)

 

 

Power Supply Requirements, Specifications, and Twist Lock Options

The requirements for Matrix X Router AC power supply modules are as follows:

Table A-2 AC Power Supply Requirements

Item

Specification

 

 

Input Frequency

50 to 60 Hz

Input (Voltage/Current)

100 to 125

Vac: 16 A

 

200 to 240

Vac: 8 A

Output Power

1160/1500 Watts

 

 

 

The power specifications for Matrix X Router modules, shown in Table A‐3, and redundancy configuration tables, shown in Table A‐4 and Table A‐5, are useful guides for power budget planning. To estimate a power budget, simply total the wattage of each installed module, making sure the combined wattage consumed is no greater than 100% of the output of the power supply(ies).

Table A-3 Module Power Specifications

 

@ 110 Vac / 220 Vac

 

 

 

Module

Power (Watts)

Thermal Output (BTU/HR)

 

 

 

CM

97 Watts

331.1 BTU/HR

 

 

 

Fan tray

85 Watts

290.1 BTU/HR

 

 

 

X4-FM

30 Watts

102.4 BTU/HR

 

 

 

X8-FM

62 Watts

211.6 BTU/HR

 

 

 

X16-FM

98 Watts

334.5 BTU/HR

 

 

 

X-G32-00

155 Watts

520.0 BTU/HR

 

 

 

X-GT16-00

105 Watts

358.3 BTU/HR

A-2 Specifications and Regulatory Compliance

Page 76
Image 76
Enterasys Networks X009-U manual Table A-2 AC Power Supply Requirements, Table A-3 Module Power Specifications