GENERAL

The SA-1heating cable controller has been designed and manufactured for the sole intended use of controlling heating cables in residential and commercial snow melting applications such as: sidewalks, driveways, parking garage entrances and drive-through. The SA-1 uses microcontroller technology to reduce energy consumption by energizing the heating cable only when the right conditions of temperature and snowfall occur.

The main components of the SA-1are shown in Fig.1. The snow and temperature sensors detect snow or ice conditions and activate, through a power relay, a heating cable.

Another feature of SA-1 is the LED indicator light. This light turns red if the snow sensor is dirty and needs to be cleaned. The red light will switch off automatically when the snow sensor is cleaned. The LED turns green every time the power relay is activated and will switch off if the power relay is off.

Improper installation, use and/or maintenance of the

SA-1 can cause fire, electrical shock and/or result in Figure 1 snow build-up.

Moisture Sensor

SA-1

Enclosure

LED Indicator

Mounting Connector

.5" (12.70mm) NPT

Temperature Sensor

WARNINGS

1.This is not a “do-it-your-self” product. A qualified electrician must install the SA-1.

2.If after carefully reading these instructions you still have questions regarding installation, operation or maintenance of this product, call the numbers listed for assistance.

3.Prior to installation, check the SA-1 body enclosure or wires for possible shipping damages. Do not install a damaged SA-1 controller.

4.All heating cables, controls & associated systems must be installed in compliance with the latest editions of all applicable electrical codes and ordinances.

5.These instructions must be saved and made available to owners or users of this product and/or transferred to future owners.

6.Any heating cable that is to be connected to the SA-1

must be installed according to the manufacturer’s instructions.

7.Do not connect more than 16 Amp load to the

SA-1 (See Fig. 2 & 3). Risk of fire, electric shock or accumulation of snow can result from a larger cable or from multiple cables being connected.

8.Secure the SA-1 in an area free of obstructions such as trees, shrubs, etc. to prevent any damages to the snow sensor.

9.Avoid excessive shock or vibration.

10.Do not touch the surface of the moisture sensor, it is a hot surface.