electrical SPECIFICATIONS and performance data
NOTE: Due to EMI’s ongoing product development program, all designs and specifications are subject to change without notice.
|
|
|
|
|
|
|
|
| ELECTRICAL SPECIFICATIONS |
|
|
|
|
|
|
|
|
|
|
| CAF TECHNICAL DATA |
| ||||||||||||||||
|
|
| STANDARD UNIT DATA |
|
|
| SMALL |
|
|
|
|
| MEDIUM |
| LARGE |
|
| CABINET DIMENSIONS | SMALL |
| MEDIUM |
| LARGE | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HEIGHT |
|
| |||||
|
|
| POWER SUPPLY |
|
|
|
|
| 230V/1PH/60HZ |
| 230V/1PH/60HZ |
| 230V/1PH/60HZ |
|
|
|
| |||||||||||||||||||||
|
|
| FULL LOAD AMPS |
|
|
| A |
| 0.4 |
|
|
|
|
|
| 0.6 |
|
|
| 0.9 |
|
| WIDTH |
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DEPTH |
|
| ||||||||||||||||||
| MIN. CIRCUIT AMPACITY (MCA) | A |
| 0.5 |
|
|
|
|
|
| 0.75 |
|
|
| 1.13 |
|
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| WEIGHT | 40 LBS. |
| 64 LBS. |
| 97 LBS. | ||||||||||||||||||||
|
|
| REC. FUSE |
|
|
|
|
| A |
| 15 |
|
|
|
|
|
| 15 |
|
|
| 15 |
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FASCIA DIMENSIONS | SMALL |
| MEDIUM |
| LARGE | |||||||||||||
|
| WITH OPTIONAL ELECTRIC HEAT 1 |
|
|
| SMALL |
|
|
|
|
| MEDIUM |
| LARGE |
|
|
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| HEIGHT |
| 3” |
| 3” | |||||||||||||||||||||
|
|
| POWER SUPPLY |
|
|
|
|
| 230V/1PH/60HZ |
| 230V/1PH/60HZ |
| 230V/1PH/60HZ |
|
|
|
| |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| WIDTH | 25” |
| 37” |
| ||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
| ELECTRIC HEAT CAPACITY | KW |
| 1.5 |
|
|
|
|
|
| 3.0 |
|
|
| 5.0 |
|
| DEPTH | 25” |
| 37” |
| 37” | |||||||||||||
|
|
| HEATER AMPS |
|
|
| A |
| 6.52 |
|
|
|
|
|
| 13.1 |
|
|
| 21.7 |
|
| WEIGHT | 5 LBS. |
| 18 LBS. |
| 21 LBS. | ||||||||||
|
|
| FULL LOAD AMPS |
|
|
| A |
| 7 |
|
|
|
|
|
| 13.7 |
|
|
| 22.6 |
|
| CONNECTIONS | SMALL |
| MEDIUM |
| LARGE | ||||||||||
| MIN. CIRCUIT AMPACITY (MCA) | A |
| 8.8 |
|
|
|
|
|
| 17.1 |
|
|
| 28.3 |
|
| CHILLED WATER INLET | 5/8” |
| 7/8” |
| 7/8” | |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| CHILLED WATER OUTLET | 5/8” |
| 7/8” |
| 7/8” | ||||||||||||||||||||
|
|
| REC. FUSE WITH HEAT |
|
| A |
| 15 |
|
|
|
|
|
| 20 |
|
|
| 30 |
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CONDENSATE | 3/8” |
| 3/8” |
| 3/8” | ||||||||||||||||
WITH OPTIONAL BOOST TRANSFORMER 2 |
| SMALL |
|
|
|
|
| MEDIUM |
| LARGE |
|
|
|
| ||||||||||||||||||||||||
|
|
|
|
|
|
|
|
| BRANCH DUCT DIAMETER | 5” |
| 5” |
| 6” | ||||||||||||||||||||||||
|
|
| POWER SUPPLY |
|
|
|
|
| 115V/1PH/60HZ |
| 115V/1PH/60HZ |
| 115V/1PH/60HZ |
| FRESH AIR DUCT DIAMETER | 3” |
| 3” |
| 3” | ||||||||||||||||||
|
|
| FULL LOAD AMPS |
|
|
| A |
| 0.8 |
|
|
|
|
|
| 1.2 |
|
|
| 1.8 |
|
| HOT WATER INLET* | 5/8” |
| 5/8” |
| 5/8” | ||||||||||
| MIN. CIRCUIT AMPACITY (MCA) | A |
| 1.0 |
|
|
|
|
|
| 1.5 |
|
|
| 2.26 |
|
| HOT WATER OUTLET* | 5/8” |
| 5/8” |
| 5/8” | |||||||||||||||
|
|
| REC. FUSE |
|
|
|
|
| A |
| 15 |
|
|
|
|
|
| 15 |
|
|
| 15 |
|
| FILTRATION | SMALL |
| MEDIUM |
| LARGE | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TYPE | WIRE FRAMED PERIFRAME | |||||||||||||||||
(1) STANDARD UNIT FITTED WITH OPTIONAL ELECTRIC HEATING ELEMEN TS. AVAILABLE WITH 230V MODEL UNITS ONLY. |
|
|
|
| ||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| QUANTITY | 1 |
| 2 |
| 3 | ||
(2) STANDARD UNIT FITTED WITH OPTIONAL BOOST TRANSFORMER FOR CONNECTION TO A 115V ELECTRICAL SUPPLY. ELECTRIC HEAT |
|
| ARRESTANCE | 80% |
| 80% |
| 80% | ||||||||||||||||||||||||||||||
IS NOT AVAILABLE WITH THIS OPTION. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CONDENSATE PUMP | SMALL |
| MEDIUM |
| LARGE | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MAXIMUM HEAD | 30” |
| 30” |
| 30” | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SOUND LEVELS (dbA) |
|
| ||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| NOMINAL FLOW RATE (GPM) | 0.1 |
| 0.1 |
| 0.1 | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Model |
|
| High |
|
| Med. |
| Low |
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Speed |
| Speed |
| Speed |
|
|
|
| * UNITS FITTED WITH OPTIONAL HOT WATER COIL ONLY |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 47 |
|
|
| 45 |
| 40 |
|
|
|
|
|
|
|
|
|
|
|
| ||||
| DISCHARGE AIR VOLUME |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
| High | Med. |
|
|
| Low |
|
|
|
| 18 |
|
| 43 |
|
|
| 41 |
| 39 |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| 20 |
|
| 47 |
|
|
| 43 |
| 41 |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
Model |
| Speed | Speed |
| Speed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
| CFM | CFM |
|
|
| CFM |
|
|
|
|
|
| 48 |
|
|
| 47 |
| 45 |
|
|
|
|
|
|
|
|
|
|
|
| |||||
| 400 | 340 |
|
|
|
| 300 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
18 |
|
| 615 | 550 |
|
|
|
| 490 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20 |
|
| 750 | 615 |
|
|
|
| 550 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| CAF CHILLED WATER CASSETTE CAPACITIES |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| COOLING CAPACITY |
|
|
|
|
|
|
|
| CHILLED WATER INLET/OUTLET °F |
|
|
|
| |||||||||||||
33 |
|
| 996 | 890 |
|
|
|
| 784 |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
36 |
|
| 1123 | 996 |
|
|
|
| 890 |
|
| MODEL | AIR ON °F |
|
|
|
|
|
| 40/50° F |
|
|
|
|
| 45/55° F |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
| DB/50% RH |
| TC Btuh |
| SC Btuh |
| FLOW GPM | P.D. FT. H20 | TC Btuh |
| SC Btuh | FLOW GPM | P.D. FT. H20 | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 72 |
|
|
|
| 5460 |
| 5460 |
| 1.2 |
| 6.7 | 4780 |
| 4440 | 1.1 |
| 5.4 | |||||
|
|
|
|
|
|
|
|
|
|
|
| 08 |
|
| 75 |
|
|
|
| 6480 |
| 6140 |
| 1.4 |
| 9.0 | 5460 |
| 5460 | 1.2 |
| 6.4 | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80 |
|
|
|
| 9550 |
| 7170 |
| 2.1 |
| 17.0 | 7500 |
| 6480 | 1.7 |
| 11.7 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 72 |
|
|
|
| 7850 |
| 7510 |
| 1.7 |
| 4.3 | 6480 |
| 6140 | 1.4 |
| 2.7 | |||||
CAF HOT WATER CASSETTE CAPACITIES |
| 12 |
|
| 75 |
|
|
|
| 10580 |
| 8190 |
| 2.3 |
| 6.7 | 8190 |
| 7510 | 1.8 |
| 4.0 | ||||||||||||||||
(Hot Water 180°F Inlet/160° F Outlet) |
|
|
|
|
| 80 |
|
|
|
| 14670 |
| 9550 |
| 3.3 |
|
| 12.0 | 12280 |
| 8530 | 2.7 |
| 8.7 | ||||||||||||||
Model |
| AIR ON °F | TC |
| Flow |
| P.D. FT. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
| 72 |
|
|
|
| 13480 |
| 12520 |
| 2.7 |
|
| 3.7 | 10100 |
| 10100 | 2.0 |
| 2.2 | ||||||||||||
DB/50% RH | Btuh |
| GPM |
| H20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
|
| 50° | 19,800 |
| 2.0 |
| 10.0 |
|
| 18 |
|
| 75 |
|
|
|
| 17310 |
| 13850 |
| 3.5 |
| 5.8 | 11670 |
| 11640 | 2.3 |
| 3.0 | ||||||||
08 |
| 60° | 17,100 |
| 1.7 |
| 8.4 |
|
|
|
|
|
| 80 |
|
|
|
| 23410 |
| 15870 |
| 4.7 |
|
| 9.0 | 17810 |
| 13780 | 3.6 |
| 6.0 | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
| 70° | 14,000 |
| 1.4 |
| 6.7 |
|
|
|
|
|
| 72 |
|
|
|
| 15050 |
| 14570 |
| 3.0 |
|
| 4.6 | 11670 |
| 11630 | 2.3 |
| 3.0 | ||||||
|
| 50° | 46,060 |
| 4.7 |
| 10.9 |
|
| 20 |
|
| 75 |
|
|
|
| 19140 |
| 15930 |
| 3.8 |
|
| 6.4 | 13510 |
| 13470 | 2.7 |
| 3.7 | |||||||
18/20 |
| 60° | 41,930 |
| 4.3 |
| 9.4 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
| 80 |
|
|
|
| 26650 |
| 18390 |
| 5.3 |
|
| 11.1 | 19990 |
| 15970 | 4.0 |
| 6.8 | |||||||||||
|
| 70° | 37,770 |
| 3.8 |
| 8.1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
| 72 |
|
|
|
| 26310 |
| 21260 |
| 5.3 |
|
| 8.5 | 17610 |
| 17570 | 3.5 |
| 5.3 | ||||||||||
|
| 50° | 62,500 |
| 6.4 |
| 10.8 |
|
| 33 |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
| 75 |
|
|
|
| 32070 |
| 23500 |
| 6.4 |
|
| 13.0 | 23060 |
| 19790 | 4.6 |
| 7.4 | ||||||||||||
33/36 |
| 60° | 56,940 |
| 5.8 |
| 9.2 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| 70° | 51,350 |
| 5.2 |
| 7.3 |
|
|
|
|
|
| 80 |
|
|
|
| 41760 |
| 26920 |
| 8.4 |
| 19.2 | 33130 |
| 23300 | 6.6 |
| 14.2 | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 72 |
|
|
|
| 28490 |
| 23300 |
| 5.7 |
|
| 10.3 | 19210 |
| 19170 | 3.8 |
| 6.0 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| 36 |
|
| 75 |
|
|
|
| 34700 |
| 25690 |
| 6.9 |
| 15.1 | 24910 |
| 21700 | 5.0 |
| 8.1 | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 80 |
|
|
|
| 45810 |
| 29480 |
| 9.2 |
| 21.0 | 35830 |
| 25450 | 7.2 |
| 15.7 |
TC = TOTAL COOLING CAPACITY, SC = SENSIBLE COOLING CAPACITY