VFHS-20/10T LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch;

do not use any phone in your building.

Immediately call yourgas supplierfrom a neighbor's

phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set thermostat (gas control knob) to lowest setting.

3.Turn off all electric power to the appliance (if appli- cable).

4.Push in gas control knob slightly and turn clockwise to "OFF". Do not force.

GAS CONTROL KNOB

SHOWN IN “OFF”

POSITION

CONTROL KNOB

INDICATOR

PIEZO IGNITOR

5.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

6.Find pilot - the pilot is attached at the bottom of the burner assembly .

7. Turn gas control knob counterclockwise

to

"PILOT."

 

8.Push in gas control knob all the way and hold in. Repeatedly push the piezo ignitor button until pilot is lit (or use a match to light pilot). Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 4 through 8.

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

9. Turn gas control knob counterclockwise

to

"HI".

 

10.Turn on all electric power to appliance (if appli- cable).

11.Set thermostat (gas control knob) to desired setting from "HI" to "LO".

TO TURN OFF GAS TO APPLIANCE

1.Set thermostat (gas control knob) to lowest setting.

2.Turn off all electric power to appliance if service is to be performed (if applicable).

3.Push in gas control knob slightly and turn clock-

wise

to "OFF". Do not force.

Page 14

16717-2-0605

Page 14
Image 14
Empire Comfort Systems VFHS-20R-4, VFHS-20/10T-4 installation instructions VFHS-20/10T Lighting Instructions, Pilot

VFHS-20R-4, VFHS-20/10T-4 specifications

Empire Comfort Systems has consistently been a frontrunner in the heating industry, and their VFHS-20R-4 and VFHS-20/10T-4 models are prime examples of their commitment to quality and innovation. Designed for efficient and effective heating solutions, these units offer unique features that cater to diverse customer needs.

The VFHS-20R-4 is part of Empire's versatile vent-free heater line, providing an impressive output of 20,000 BTUs. Its design allows for flexible installation options, making it ideal for both residential and commercial applications. One of the standout features of the VFHS-20R-4 is its advanced heating technology, which utilizes radiant heat to warm your space quickly and efficiently. This method not only provides powerful heat but also enhances comfort by distributing warmth evenly.

Furthermore, the VFHS-20R-4 includes a built-in safety pilot system that ensures safe operation. This technology detects any malfunctions and automatically shuts the unit off if necessary, providing peace of mind for users. Additionally, the unit's thermostatic control allows for easy temperature management and helps maintain an energy-efficient environment.

On the other hand, the VFHS-20/10T-4 model is tailored for areas requiring a dual heating approach. This innovative unit combines both vent-free and vented heating options, offering flexibility based on user preferences or regulatory requirements. With a heat output of 20,000 BTUs, it delivers ample warmth while also featuring a compact design that seamlessly fits into various spaces.

Both models boast a sleek and modern aesthetic, ensuring they complement any decor. They are available in multiple finishes, allowing users to choose the one that best suits their style. The ease of installation is another significant advantage, with straightforward instructions enabling users to set up the units with minimal hassle.

In terms of energy efficiency, both the VFHS-20R-4 and VFHS-20/10T-4 are equipped with technologies that minimize energy consumption while maximizing heat output. Their environmentally friendly design helps reduce emissions, making them suitable options for eco-conscious consumers.

In conclusion, the Empire Comfort Systems VFHS-20R-4 and VFHS-20/10T-4 models represent the pinnacle of heating technology. With their efficient features, safety enhancements, and stylish designs, they stand out as excellent choices for anyone seeking reliable and effective heating solutions in their living or working spaces. Whether you need a versatile heating option or a dual-function solution, Empire Comfort Systems delivers with these remarkable models.