Enerco 3500DF owner manual General Recommendations, Technical Specifications, MH3500 DF, MH 6000DF

Models: 3500DF

1 24
Download 24 pages 41.44 Kb
Page 3
Image 3
GENERAL RECOMMENDATIONS

IMPORTANT

Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods or persons due to improper use of units.

GENERAL RECOMMENDATIONS

heater exhausts hot air and the combustion products into the room, while those with indirect combustion are fitted with a flue to take the fumes away through the chimney.

Always follow local ordinances and codes when using this heater:

Read and follow this owner’s manual before using the heater.

content.

materials (the minimum distance must be 6 ft.).

TECHNICAL SPECIFICATIONS

to the heater requirements. Direct combustion heaters should only be used in well vented areas in order to avoid carbon monoxide poisoning.

Never block air inlet (rear) or air outlet (front).

In case of very low temperatures add kerosene to the heating oil.

Make sure heater is always under surveillance and keep children and animals away from it;

Before starting the heater always check free rotation of ventilator fan.

Unplug heater when not in use.

TECHNICAL SPECIFICATIONS

 

MH3500 DF

MH 6000DF

 

HS 3500DF

HS 6000DF

 

 

 

 

 

 

 

 

 

 

Heat input

 

[kBTU/h]

360

600

 

 

 

 

 

 

Air Flow

 

[cfm]

1795

2.800

 

 

 

 

 

 

Fuel Type

 

 

Diesel/Kerosene/#1-2 Fuel Oil

 

 

 

 

 

 

Heat output

 

[kBTU/h]

-

-

 

 

 

 

 

 

Fuel consumption

 

[gal/h]

2..6

4.32

 

 

 

 

 

[lb/h]

18.56

30.84

 

 

 

 

 

 

 

 

 

 

 

Phase

 

1

1

 

 

 

 

 

 

Power supply

 

Voltage

[V]

120

120

 

 

 

 

 

 

 

 

Frequency

[Hz]

60

60

 

 

 

 

 

 

Electric consumption

[W]

632

1,240

 

 

 

[A]

6.00

11.10

 

 

 

 

 

 

 

 

Nozzle

 

[USgal/h]

2.00-80° S

3.00-80°S

 

 

 

 

 

Pump pressure

 

[psi]

174

203

 

 

 

 

 

Max static pressure

 

[in WC]

-

-

 

 

 

 

Recommended max. temp. in the air

[°F]

-

-

duct

 

 

 

 

 

 

 

 

 

 

 

Adjustment of combustion air Flap

[in]

a=0.394

a=0.866

 

 

 

-

-

 

 

 

 

 

 

 

 

Flue diameter

 

[in]

-

-

 

 

 

 

Compulsory Flue draft

[in WC]

-

-

 

 

 

 

 

Tank capacity

 

[gal]

35.6

35.6

 

 

 

 

Dimensions, L x W x H

[in]

56.4x26.38x38.3

68.5x28.8x44

 

 

 

 

 

Net Weight

 

[lb]

153

243

 

 

 

 

 

 

ENERCO GROUP, INC. Direct Fired Portable Heater

3

Operating Instructions and Owner’s Manual

Page 3
Image 3