Maintenance

The hot air generators with wheels must be wheeled. The suspended version which has no wheels must be transported with adequate machinery.

Maintenance

Preventive and regular maintenance will ensure a long trouble free life to your heater.

COLUMN INTENTIONALLY LEFT BLANK Warning

Never service heater while it is plugged in, operating or hot.

Severe burns or electrical shock can occur.

Every 50 hours of operation: disassemble filter and wash with clean oil, remove upper body parts and clean inside and ventilator with compressed air, check correct attachment of H.V. connectors to the electrodes and check H.V. cables, remove burner assembly, clean and check electrode settings, adjust according to scheme “gap OF ELECTRODES”.

COLUMN INTENTIONALLY LEFT BLANK

ENERCO GROUP, INC. Direct Fired Portable Heater

5

Operating Instructions and Owner’s Manual

Page 5
Image 5
Enerco 3500DF owner manual Maintenance, Column Intentionally Left Blank