Enerco HS300ID manual Specifications, Appliance Description, Installation Instructions, Clearances

Models: HS300ID HS180ID

1 8
Download 8 pages 29.97 Kb
Page 3
Image 3
SPECIFICATIONS

SPECIFICATIONS

MODEL #

180

300

Thermal power (BTU/hr)

181,000

289,000

Air Flow Rating (ft³/min)

1475

2650

Oil Consumption (gal/hr)

1.29

2.06

Fuel Nozzle

1.00 60° H

1.50 80° W

Efficiency (%)

87.1

88.5

Noise Level at 2m (dB(A))

73

73

Voltage (V)

110V 60Hz 1ph ....

110V 60Hz 1ph

Electrical Power (W)

460

800

Current Rating (A)

7.0

12.0

Weight (lb)

167

267

Length (in)

55

66

Width (in)

24

27

Height (in)

31

37

Flue Diameter (in)

6

6

Tank Capacity (gal)

14

26

Fuel Pressure (psi)

175

175

Air Lock Setting

2

5.5

APPLIANCE DESCRIPTION

Mobile space heater with:

closed combustion chamber and gas exhaust duct (indirect- fired models)

open combustion chamber (direct-fired models)

INSTALLATION INSTRUCTIONS

General instructions

The heater must be operated only by properly trained personnel. The manufacturer’s instructions must be followed.

The heater must be installed and operated so that people are not exposed to dangers deriving from exhaust gases, from the hot air flow and in such a way that no fire risks exist.

It is forbidden to install the heater in the surroundings of flammable materials, combustible products, or in places where explosion risk exist.

When the heater is used in a closed room, ensure a minimum volume of 28,300 ft³ for the HS180ID model and 53,000 ft³ for the HS300ID model and a continuous natural air circulation through windows and doors. For a good combustion, provide approximately 47 cfm air flow from outside.

For the use of the heater the general and special fire safety regulations in force in all fields of applications must be followed. In any case the following minimum safety clearances from materials or objects in the surroundings of the heater must be ensured:

Clearances:

Sides:

2.5 ft

Air inlet:

2.5 ft

Top:

6 ft

Air outlet:

12 ft

 

 

 

 

Floors and ceilings must be made of fireproof materials in the room where the heater is operated.

The air inlet and outlet must never be blocked for any reason.

Install the heater on a flat, level floor in a steady position.

It is forbidden to connect direct-fired heaters to air ducts.

Maintenance and checks

Depending on the operational conditions, usually every year, the heater should be checked by qualified personnel.

Prior to start-up, the user must check for any evident non- compliance with rules of use, safety and protection.

INSTRUCTIONS FOR USE

Start-up

The heater is factory set for operation without room thermostat.

If operation with room (remote) thermostat is desired, remove the socket cover (Fig.1, No.1) and insert the thermostat plug into the socket.

Fill the tank with proper fuel.

24

1 3

Figure 1

Connect the supply plug to a 110V ~ 60 Hz single phase earthed socket. The green lamp indicates that the heater is powered.

WARNING: THE APPLIANCE MUST BE GROUNDED

ENERCO GROUP, INC. Indirect Fired Portable Heater

3

Operating Instructions and Owner’s Manual

Page 3
Image 3