SPECIFICATIONS
MODEL # | 180 | 300 |
Thermal power (BTU/hr) | 181,000 | 289,000 |
Air Flow Rating (ft³/min) | 1475 | 2650 |
Oil Consumption (gal/hr) | 1.29 | 2.06 |
Fuel Nozzle | 1.00 60° H | 1.50 80° W |
Efficiency (%) | 87.1 | 88.5 |
Noise Level at 2m (dB(A)) | 73 | 73 |
Voltage (V) | 110V 60Hz 1ph .... | 110V 60Hz 1ph |
Electrical Power (W) | 460 | 800 |
Current Rating (A) | 7.0 | 12.0 |
Weight (lb) | 167 | 267 |
Length (in) | 55 | 66 |
Width (in) | 24 | 27 |
Height (in) | 31 | 37 |
Flue Diameter (in) | 6 | 6 |
Tank Capacity (gal) | 14 | 26 |
Fuel Pressure (psi) | 175 | 175 |
Air Lock Setting | 2 | 5.5 |
APPLIANCE DESCRIPTION
Mobile space heater with:
•closed combustion chamber and gas exhaust duct (indirect- fired models)
•open combustion chamber
INSTALLATION INSTRUCTIONS
General instructions
•The heater must be operated only by properly trained personnel. The manufacturer’s instructions must be followed.
•The heater must be installed and operated so that people are not exposed to dangers deriving from exhaust gases, from the hot air flow and in such a way that no fire risks exist.
•It is forbidden to install the heater in the surroundings of flammable materials, combustible products, or in places where explosion risk exist.
•When the heater is used in a closed room, ensure a minimum volume of 28,300 ft³ for the HS180ID model and 53,000 ft³ for the HS300ID model and a continuous natural air circulation through windows and doors. For a good combustion, provide approximately 47 cfm air flow from outside.
•For the use of the heater the general and special fire safety regulations in force in all fields of applications must be followed. In any case the following minimum safety clearances from materials or objects in the surroundings of the heater must be ensured:
Clearances:
Sides: | 2.5 ft | Air inlet: | 2.5 ft |
Top: | 6 ft | Air outlet: | 12 ft |
|
|
|
|
•Floors and ceilings must be made of fireproof materials in the room where the heater is operated.
•The air inlet and outlet must never be blocked for any reason.
•Install the heater on a flat, level floor in a steady position.
•It is forbidden to connect
Maintenance and checks
•Depending on the operational conditions, usually every year, the heater should be checked by qualified personnel.
•Prior to
INSTRUCTIONS FOR USE
Start-up
•The heater is factory set for operation without room thermostat.
•If operation with room (remote) thermostat is desired, remove the socket cover (Fig.1, No.1) and insert the thermostat plug into the socket.
•Fill the tank with proper fuel.
24
1 3
Figure 1
•Connect the supply plug to a 110V ~ 60 Hz single phase earthed socket. The green lamp indicates that the heater is powered.
•WARNING: THE APPLIANCE MUST BE GROUNDED
ENERCO GROUP, INC. Indirect Fired Portable Heater | 3 | Operating Instructions and Owner’s Manual |