TROUBLE

CAUSE

SOLUTION

Heater does not start

•No power

•Check main distribution board and power supply line

 

•Faulty cable/connections

•Check/have cable replaced by a qualified electrician

 

•Burnt fuse

•Check and replace if required

 

•Room thermostat set too low

•Set room thermostat on a higher temperature

 

•Thermostat socket cap not inserted

•Insert cap into the thermostat socket

 

•The safety thermostat has been activated

•Reset the safety thermostat

 

 

 

Heater starts, flame ignites

•Dirty or faulty flame sensor

•Clean or replace

but then heater locks out

•Faulty burner control unit

•Contact service personnel

Heater starts, flame does not ignite and then heater locks out

•Clogged nozzle

•Clean or replace

•Flame sensor receives an external

•Check for external lights (sun, lamps, etc.)

light signal during ignition sequence

 

•Faulty burner control unit

•Contact service personnel

•No fuel

•Fill tank

•Ignition fault, dirty or incorrectly

•Clean electrodes, contact service personnel if required

spaced electrodes

 

Heater starts, but

•Dirty or blocked nozzle

•Clean or replace

combustion is not good

•Clogged filters

•Clean or replace

 

•Leakes in fuel circuit

•Check and eventually replace

 

•Oil pump provides low pressure

•Contact service personnel

 

•Insufficient combustion air

•Wrong air lock setting

 

•Insufficient ventilation air

•Contact service personnel

 

 

 

Heater stops due to safety

 

 

thermostat

•The appliance has overheated

•Contact service personnel

 

•Faulty safety thermostat

•Contact service personnel