Enerco HS50KT Specifications, Operating Precautions, Safety Precautions, Operating Instructions

Models: MH125KT HS50KT HS75KT HS125KT HS175KT MH175KT MH50KT MH75KT

1 8
Download 8 pages 49.4 Kb
Page 3
Image 3

SPECIFICATIONS

Type of Fuel: For use with Kerosene or #1 Fuel Oil ONLY on ALL models.

Model

50K

75KT

125KT

175KT

Burn Rate:

50,000 Btu/hr (15 kW)

75,000 Btu/hr (22 kW)

125,000 Btu/hr (37 kW)

175,000 Btu/hr (51 kW)

Fuel Rate:

0.37 gal/hr (1.4 L/hr)

0.55 gal/hr (2.1 L/hr)

0.96 gal./hr (3.5 L/hr)

1.3 gal/hr (5.0 L/hr)

Electrical Input:

115V, 60Hz, 3.5a

115V, 60Hz, 4a

115V, 60Hz, 5.5a

115V, 60Hz, 5.5a

Line Protection:

10 amps

10 amps

20 amps

20 amps

Min. Operating Voltage:

110V

110V

110V

110V

Pressure Setting:

3.5 psig (24 kPa)

4.2 psig (29 kPa)

5.0 psig (34 kPa)

5.8 psig (40 kPa)

Max. Outlet Temperature:

1300oF (704oC)

1300oF (704oC)

1300oF (704oC)

1300oF (704oC)

Fuel Tank Capacity:

4 gallons (15.1 L)

6 gallons (22.7 L)

14 gallons (53 L)

14 gallons (53 L)

Ignition:

Direct Spark, Continuous

Direct Spark, Continuous

Direct Spark, Continuous

Direct Spark, Continuous

Spark Generator:

Igniter 13 kV, 10ma

Igniter 13 kV, 10ma

Igniter 13 kV, 10ma

Igniter 13 kV, 10ma

Primary Safety Control:

Solid State Control

Solid State Control

Solid State Control

Solid State Control

Certification:

 

 

 

 

OPERATING PRECAUTIONS

This is a kerosene, direct-fired, forced air heater. It's intended use is primarily temporary heating of buildings under construction, alteration or repair.

Direct-Fired means that all of the combustion products enter the heated space. Even though this heater operates very close to 100 percent combustion efficiency, it still produces small amounts of carbon monoxide. Carbon monoxide (called CO) is toxic. We can tolerate small amounts but not a lot. CO can build up in a heated space and failure to provide adequate ventilation could result in death. The symptoms of inadequate ventilation are:

headache

dizziness

burning eyes and nose

nausea

dry mouth or sore throat

So, be sure to follow advice about ventilation in these operating instructions.

Forced Air means that a blower or fan pushes the air through the heater. Proper combustion depends upon this air flow; therefore, the heater must not be revised, modified or operated with parts removed or missing. Likewise, safety systems must not be circumvented or modified in order to operate the heater.

When the heater is to be operated in the presence of other people the user is responsible for properly acquainting those present with the safety precautions and instructions, and of the hazards involved.

SAFETY PRECAUTIONS

1.Check the heater thoroughly for damage. DO NOT operate a damaged heater.

2.DO NOT modify the heater or operate a heater which has been modified from its original condition.

3.Use only Kerosene. Never use gasoline, naphtha, paint thinner, alcohol or other fuels of any kind.

4.For indoor use only. Not for use where exposed to weather.

5.Use in well ventilated areas, provide at least 2 sq. ft. (0.19 sq. m.) of opening near the floor and 2 sq. ft. (0.19 sq. m.)

near the ceiling directly to outdoors. Increase air openings as marked for each additional heater.

6.Always keep combustibles, like paper and wood at least 8 ft. (2.4 m) from the heater outlet and 3 ft. (1.0 m) from the top, sides and inlet. Locate 10 ft. (3.0 m) from canvas or plastic coverings and secure them to prevent flapping movement.

7.Caution: Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing ignition. Do Not Touch. Keep Children, Clothing, and Combustibles away.

8.Install the heater such that it is not directly exposed to water spray, rain and / or water.

9.Never use in areas normally for habitation and /or where children may be present.

10.Operate only on a stable, level surface. (MH50K & MH75KT

– See wood floor warning).

11.Do not use with duct work. Do not restrict inlet or exit.

12.Use only with electrical power specified. The electrical connection and grounding must comply with National Electrical Code – ANSI/NFPA 70 (USA) and CSA C22.1 Canadian Electrical Code, Part 1 (Canada).

13.Use only a properly grounded 3-prong receptacle or extension cord.

14.Do not move, handle, or service while hot or burning.

15.Use only in accordance with local, state (provincial) or National requirements, ordinances and codes.

OPERATING INSTRUCTIONS

UNPACKING

1.Remove all protective material which may have been applied to the heater for shipment.

2.Remove heater from carton.

3.Check the heater for possible shipping damage. If any damage is found immediately notify the dealer from whom you purchased the heater.

ASSEMBLY (For 125,000 and 175,000 BTU/hr models only)

Wheel and handles are found in the shipping carton along with mounting hardware. The wheels, axle and mounting hardware are in a package. Tools required are a 5/16" nutdriver, 3/8" open or adjustable wrench and standard pliers.

Enerco Group, Inc. Kerosene Forced Air Heater

3

Operating Instructions and Owner’s Manual

Page 3
Image 3
Enerco HS50KT, MH125KT, MH50KT Specifications, Operating Precautions, Safety Precautions, Operating Instructions, Unpacking