Enerco TSBF20LPT, TSBF10LP, MHBF10LP, HSBF10LP What To Do If You Smell Gas, Thermostat Models

Models: MHBF20LPT TSBF20LPT MHBF10LP TSBF10LP HSBF20LPT HSBF10LP

1 24
Download 24 pages 23.88 Kb
Page 11
Image 11
THERMOSTAT MODELS

TO TURN OFF GAS TO APPLIANCE

SHUTTING OFF HEATER:

1.Turn control knob clockwise to the OFF position.

2.Turn off all electrical power to the appliance if servicing is to be preformed.

3.Turn off equipment shutoff valve.

SHUTTING OFF BURNER ONLY (PILOT STAYS LIT)

1.Turn control knob clockwise to the PILOT/IGN position.

OPERATING YOUR HEATER

THERMOSTAT MODELS

IR20LPT, IR30LPT, BF20LPT, BF30LPT,

FOR YOUR SAFETY READ BEFORE LIGHTING

IR20LPT, IR30LPT, BF20LPT, BF30LPT, WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by pushing the ignitor button. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you can not reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If knob will not push in or turn by hand, don’t try to repair it. Call a qualified service technician or gas supplier. Forced or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been underwater.

LIGHTING INSTRUCTIONS

1.STOP! Read the all safety information included with and on the side of heater.

2.Make sure the equipment shutoff valve is fully open.

3.Push in gas control knob and slightly turn clockwise to the OFF position (see figure 19).

4.Wait five (5) minutes. Then smell for gas including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step.

5.Push in and turn control knob counterclockwise to PILOT/IGN. Press in control knob for five (5) seconds.

Note: The first time that the heater is operated after connecting the gas supply, the control knob should be depressed for about 30 seconds. This will allow air to bleed from the gas system.

Ignitor Button

Control Knob

Figure 19.

6.With control knob pressed in, push down and release the ignition button. This will light pilot. If needed, keep pressing igniter button until pilot lights.

7.Keep control knob pressed in for (30) seconds after lighting pilot. After 30 seconds, release control knob.

Figure 20

If pilot does not stay lit, refer to Troubleshooting, pages 14 & 15. Also, contact a qualified service person or gas supplier for repairs.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

11Installation instructions and Owner’s Manual

Page 11
Image 11
Enerco TSBF20LPT, TSBF10LP, MHBF10LP What To Do If You Smell Gas, Thermostat Models, IR20LPT, IR30LPT, BF20LPT, BF30LPT