installed in that space, and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kW) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the uncon- fined space.

*Adjoining rooms are communicating only if there are doorless passageways or ventilation grilles between them.

DETERMINING THE TYPE OF HEATER LOCATION SPACE:

Use this method to determine if you have a confined or unconfined space.

Note: the space includes the room in which you install heater plus any adjoining rooms with doorless passageways or ventilation grilles between the rooms.

1.Find the volume of the space by multiplying room length x width x height.

Example: Space size 18ft (length) x 18ft. (width) x 8ft. (height) = 2592

If additional ventilation to adjoining room is supplied with grilles or openings, add the volume of these rooms to the total volume of the space.

2.Divide the space volume by 50 cubic feet to deter- mine the maximum Btu/hr the space can support.

Example: 2592 cu.ft. (volume of space) / 50 cu.ft. = 51.8 or 51,800 (maximum Btu/hr the space can support)

WARNING: If the area in which the heater may be operated is smaller than defined as an unconfined space or if the building is of unusually tight construc- tion, provide adequate combustion and ventilation air by the methods described in the National Fuel Gas Code, NFPA 54/ ANSI Z223.1, Section 5.3 or applicable local codes.

3.Add the Btu/hr of all the fuel-burning appliances in the space such as, Vent–free heater, Gas water heater, Gas furnace, Vented gas heater, Gas fireplace logs, and Other gas appliances*

*Do not include direct-vent gas appliances. Direct- vent draws combustion air from the outdoors and vents to the outdoors.

Example:

 

Gas water heater

40,000 Btu/hr

Vent Free Heater +

20,000 Btu/hr

Total

=60,000 Btu/hr

4.Compare the maximum Btu/hr the space can support with the actual amount of Btu/hr used.

Example: 51,800 Btu/hr (maximum Btu/hr the space can support)

60,000 Btu/hr (Actual amount of Btu/hr used)

The space in the above example is a confined space because the actual Btu/hr used is more than the maximum Btu/hr the space can support.

You must provide additional fresh air. Your options are as follows:

A. Rework worksheet, and the space of an adjoining room. If the extra space provides an unconfined space, remove door to adjoining room or add ventila- tion grilles between the rooms. See Ventilation Air From Inside Building (Fig. 2)

B. Vent room directly to the outdoors. See Ventilation Air From Outdoors (Fig. 3).

C. Install a lower Btu/hr heater if lower Btu/hr size makes room unconfined.

If actual Btu/hr used is less than the maximum Btu/ hr the space can support, the space is an uncon- fined space. You will need no additional fresh air ventilation.

VENTILATION AIR

Ventilation from Inside Building

This fresh air would come from an adjoining unconfined space. When ventilation to an adjoining unconfined space, you must provide two permanent openings: one within 12” of the ceiling and one within 12” of the floor on the wall connecting the two spaces (see options 1 & 2 of fig. 2). You can also remove door into adjoining room (see option3, fig 2). Follow the National Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

 

 

12”

Ventilation

Or remove

Ventilation Grilles

door into

into Adjoining Room

Grilles into

Adjoining

- Option 2

Adjoining

Room -

 

Room -

Option 3

 

Option 1

 

 

 

 

12”

Figure 2

WARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined space must have enough fresh air to supply all appliances in both spaces.

4 Installation instructions and Owner’s Manual 70575 Rev. E 04/07

Page 4
Image 4
Enerco MHBF20LPT Determining the Type of Heater Location Space, Ventilation AIR, Ventilation from Inside Building

MHBF20LPT, TSBF20LPT, MHBF10LP, TSBF10LP, HSBF20LPT specifications

The Enerco MHBF10LP, TSBF10LP, HSBF10LP, HSBF20LPT, and TSBF20LPT are innovative heating solutions designed for both commercial and residential applications. These units are highly efficient gas-fired heaters offering versatile heating capabilities, ensuring user comfort in various settings.

The MHBF10LP is a liquid propane heater featuring a powerful output of 10,000 BTU. It operates with a direct ignition system, allowing for quick and reliable startups. Its compact design makes it suitable for smaller spaces, while the adjustable heat settings empower users to customize their warmth. The MHBF10LP boasts a safety shut-off system which enhances the overall safety of the unit.

In contrast, the TSBF10LP is engineered for portability, offering the same 10,000 BTU output but with added mobility features. It comes with a built-in carrying handle and lightweight design, making it easy to transport from one location to another. Perfect for job sites or outdoor events, it features a sturdy construction that withstands demanding environments and a direct ignition system for ease of use.

The HSBF10LP, another variant in this range, offers high-efficiency heating in a small footprint. This model stands out with its integrated fan that aids in even heat distribution. Users can quickly warm up spaces without the long wait times. Additionally, it provides options for permanent installation, making it an adaptable choice for various applications.

The HSBF20LPT and TSBF20LPT models deliver enhanced power with a heating capacity of 20,000 BTU. The HSBF20LPT focuses on high efficiency and user convenience, featuring an automatic thermostat control to maintain desired temperatures without constant adjustment. Its robust design is perfect for larger areas, ensuring consistent warmth and comfort.

On the other hand, the TSBF20LPT is portable like its 10,000 BTU counterpart but with double the capacity. Its rugged construction and portability make it ideal for both indoor and outdoor use. The unit's reliability in diverse conditions is coupled with an ease of operation, providing warmth where it's most needed.

All models in this Enerco range prioritize user safety and efficiency. Featuring built-in safety mechanisms such as flame failure protection and tip-over shut-off systems, each heater ensures safe operation. Furthermore, the robust construction and high-quality materials used in these devices promise durability, making them a worthwhile investment for long-term heating needs.