Best use of Battery Power

Make sure any appliances are energy efficient and turned off after use. Use Compact Florescent Lamps. Wherever possible, charge with Solar Panels or Wind Generators. Do not allow lead acid batteries to remain discharged for long periods of time, they lose capacity (amp hours).

Disposal / Recycling of Inverter / California Proposition 65

Electronic products are known to contain materials that are toxic if improperly disposed. Contact local authorities for disposal and recycling information.

This inverter is certified to be “lead free.” Transformers in this inverter contain nickel composites. Nickel is a known neuro-toxin if ingested.

Troubleshooting

PROBLEM: No Input Voltage

Reason

Solution

 

 

Poor contact with battery

Shut down inverter and

disconnect. Clean terminals

terminals.

thoroughly and reconnect.

 

 

Turn off inverter. Fix problem.

Blown DC battery fuse(s).

Replace fuse(s) with same type

 

and rating.

 

 

PROBLEM: Inverter is Shut Down

Reason

Solution

 

 

Battery voltage below 10

Charge or replace battery.

Volts.

 

Inverter is too hot (thermal

Allow inverter to cool. Check

for adequate ventilation. Re-

shut down mode). Will be

duce the load on the inverter

indicated on LCD panel.

to rated continuous power.

 

Unit may be defective.

See warranty and call

customer service.

 

 

 