Energizer manual Rear Panel EN900 / EN1100, Determining the DC Power Requirements

Models: EN1100

1 19
Download 19 pages 44.95 Kb
Page 7
Image 7
Rear Panel EN900 / EN1100

Rear Panel EN900 / EN1100

F.High-Speed Cooling Fan. When the temperature inside the inverter exceeds a preset limit, the Cooling Fan automatically turns on to cool the inverter. When the temperature reduces, the fan turns off.

G.Negative Power Input Terminal.

H.Positive Power Input Terminal.

I.Remote Control Receptacle.

J.Ground Terminal.

Determining the DC Power Requirements

Powering multiple appliances from the high-power EN900 / EN1100 inverter requires a 12 volt bank of batteries (several batteries). To calculate the approximate power in amps a 12 volt battery bank has to supply you need to know the current, or amps required for powering the continuous AC load.

A shortcut method is to divide the continuous AC load wattage by 10. For example, the continuous AC load is 900 watts. The current (amps) is: 900/10 or 90 amps at 12 VDC. Add to the load any DC appliances that may be powered by the battery bank.

7

Page 7
Image 7
Energizer manual Rear Panel EN900 / EN1100, Determining the DC Power Requirements