England's Stove Works 55TRP22, 55SHP22 manual Installing the PU-DTSTAT

Models: 55TRP22 55SHP22

1 3
Download 3 pages 22.8 Kb
Page 1
Image 1
Pellet Stoves

Pellet Stoves

Wood Stoves

Gas Stoves

Multi-Fuel Stoves

P.O. Box 206 Monroe, VA 24574 www.englanderstoves.com Phone: (800) 516-3636 Fax: (434) 929-4810

Installing the PU-DTSTAT

BEFORE BEGINNING THERMOSTAT INSTALLATION BE CERTAIN THE STOVE IS UNPLUGGED AND COMPLETELY COOL. DEPENDING ON WHICH STOVE THE THERMOSTAT IS BEING INSTALLED ON, THE CONTROL BOARD MAY NEED TO BE REMOVED FOR INSTALLATION.

1.Using a small, slotted screwdriver (often referred to as a jeweler’s screwdriver), loosen the two screws on the front of the J18 thermostat terminal, shown below and remove the jumper which is installed in the terminal from the factory. This jumper should be set aside and saved.

Connect

thermostat wires here (J18)

2.Insert one of the thermostat wires into each of the terminals on the bottom of the J18 thermostat connection block and tighten the screws on the front of the thermostat terminal. The thermostat wires should be securely held in place by these screws (remember that the thermostat is not polarity specific, so it will not matter which wire goes into either terminal).

Page 1
Image 1
England's Stove Works 55TRP22 manual Installing the PU-DTSTAT, Pellet Stoves Wood Stoves Gas Stoves Multi-Fuel Stoves