Technical Considerations
Mid-Span Power Hub 24-Port User’s Guide 2-3
Technical Considerations
The EnterasysNetworks 24-port Mid-Span Power Hub may be placed on a shelf or
mounted in a standard 48.26-centimeter (19-inch) rack.
Before you mount the unit to a fixed location, consider the following:
Determine optimal placement.
Collect and document network information as required.
Ensure that the length of cable from the Ethernet network source to the powered
device does not exceed 100 meters.
This unit is intended for installation in a wiring closet.
Connect the unit to a grounding type AC outlet (100-240 VAC), using the standard
power cord shipped with the unit, or a user-supplied UPS (uniterruptible power
supply).
Allow for easy access to disconnect the unit from the AC outlet if necessary.
Do not cover the unit or block the airflow with any other objects. Keep the unit away
from excessive heat, humidity, vibration, and dust.
Ensure that installation conforms to local regulations.
Note: The unit is not a repeater and does not amplify the Ethernet data signal.
Caution: Observe the following requirements when mounting the Enterasys Networks
24-port Mid-Span Power Hub: