Enviro 2100 owner manual Installation, Mark the position for the ceiling hole by using a plumb bob

Models: 2100

1 20
Download 20 pages 53.64 Kb
Page 13
Image 13
2.Mark the position for the ceiling hole by using a plumb bob.

Installation

OUTSIDE AIR:

A 4” (10.2 cm) fresh air adapter kit is available. This adapter can be installed either on the back pedestal or through the floor under the pedestal.

Place the 1⁄4” mesh screen between the fresh air adapter and the body of the pedestal (as shown to right).

NOTE: Fresh air connection to the unit must be a non combustible pipe, example: 4” (10.2 cm) single wall aluminum flex pipe.

NOTE: Remove the 4” (10.2 Cm) knock out on the rear of the pedestal if room air is to be used for combustion air

INSTALLATION OF A LISTED, FACTORY BUILT CHIMNEY:

���� �� ��������

1.Set floor protector and stove in location in accordance with the “Clearances To Combustibles - Freestanding”

2.Mark the position for the ceiling hole by using a plumb bob.

3.Move this location, if necessary, to avoid floor joists, ceiling rafters while still maintaining required clearances.

4.Mark the hole for the outside air kit.

5.Move the stove out of the way.

6.Cut a pilot hole in the ceiling.

7.Cut a hole for the ceiling penetration components and frame in the sides of the hole in both the ceiling and roof. Check, and follow chimney manufacturer’s instructions for all of these steps.

8.Install the support box and chimney through the roof. Install the slip section for the chimney connector.

9.Slip the roof flashing over the chimney and secure to the roof, being careful to keep the pipe centered in the opening. To meet the code, the chimney must extend above the roof at least 3 feet (91.4 cm), and 2 feet (60.9 cm) above any area of the roof, within 10 feet (304.8 cm) of the end of the chimney.

10.Be sure all pieces including outside rain cap, flange, collar and pipe are installed and then place the stove back into position.

11.Install the smoke pipe with the lower (crimped) edge of the pipe inside the smoke collar. Any creosote formed will then run back down into the stove. All connections must be tight and secured with three sheet metal screws equally spaced.

12.Also install an outside air flex pipe to the stove.

13

Page 13
Image 13
Enviro 2100 owner manual Installation, Mark the position for the ceiling hole by using a plumb bob