Enviro 25BV owner manual Trouble Shooting, Problem Possible Cause Solution

Models: 25BV

1 19
Download 19 pages 13.2 Kb
Page 14
Image 14

11. TROUBLE SHOOTING

Problem

Possible Cause

Solution

Spark will not arc to the pilot after

Defective piezo ignitor

Check connections to ignitor

repeated pressing of spark ignitor

 

-If ignitor connections are good but there is no

 

 

spark-replace ignitor

 

 

 

 

Broken spark electrode

-Check for broken ceramic insulation

 

 

replace, electrode if broken

 

 

 

 

Miss-aligned spark electrode

-If spark is not arcing from the electrode to pilot-

 

 

adjust by loosening screws on pilot base.

 

 

Adjust away from burner and re-tighten

 

 

 

Pilot will not remain lit

Problem with thermocouple circuit

-Check for proper connection of thermocouple

 

 

to rear of valve. If loose, tighten lightly

 

 

-Check pilot for full flame impingement around

 

 

thermocouple. If the pilot is to small - Check

 

 

gas pressure, adjust pilot rate screw, check pilot

 

 

head for blockage.

 

 

-Check thermocouple voltage at rear of valve-

 

 

must be greater than 5 mV. If low , replace

 

 

thermocouple.

 

 

 

 

Air in gas line - (Pilot flame dies while

-Bleed line.

 

knob is depressed.)

-Check gas line pressure.

 

 

-Contact dealer.

 

 

 

Burners will not remain lit

Problem with thermopile circuit

-Check gasline pressure.

 

 

-Check for flame impingement on thermopile, if

 

 

low see “Pilot will not stay lit”

 

 

-Check thermopile for a Minimum of 300 mV

 

 

when burner switched on.

 

 

-Check wiring to thermostat for breaks.

 

 

BV only: - Check for spillage at draft hood that

 

 

may trip spill switch.

 

 

 

Flame lifting

- Leak in vent pipe

-check for leaks in vent connections

 

- Improper vent configuration

-check vent configuration with manual

 

- Terminal may be recirculating flue

-check to see if terminal is on correctly

 

gases

-May need to install high wind termination cap

 

 

-contact dealer.

 

 

 

BV only: insufficient air for

- Air tight house

- supply make up air to the unit.

combustion

- A Vacuum in room due to other air

 

 

moving device

 

 

 

 

Glass fogs up

Normal conditions - after the appliance warms up glass will clear

 

** Due to additives in gas, glass may get hazy during normal use**

 

Clean when needed.

 

 

 

Blue flames

Normal during start - flame will yellow as the appliance heats up.

 

 

 

Flames are burning “dirty” or Sooting

Flame impingement

-check log position

 

 

-increase primary air by opening venturi

 

 

shutters

 

 

see also “Burners will not stay lit”

 

 

 

14