Figure 3: Thermostat Switch in
MANUAL position.

Operating Instructions

OPERATING YOUR PELLET STOVE:

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. Keep hopper lid closed except during re-fuelling.

CAUTION: When operating during adverse weather, such as high winds or freezing rain, if the unit exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust outlet.

PRE-BURN CHECK: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube. Check the hopper for enough pellets to start the unit.

Note: The thermostat mode can be changed during normal



operation.



 



MANUAL MODE:

 

 

 

 

 

 

 

 

 

All control of circuit board function is adjusted at the circuit board.

To START: Press the ON / OFF button. The stove will turn on. The system light will flash. The Auger Light will flash with each pulse of the

auger (the Auger Feed Rate is pre-programmed during start-up). The

Heat Level Indicator will show the Heat Level that the stove will run at after start-up.

If this is the first time the unit has been started or the unit has run out of fuel, the auger will need to be primed. Press the Manual Auger Feed button until fuel starts to drop into the Burn Pot Liner (see

“OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).

When a fire has been established, the System Light will turn solid and the convection blower will turn on (after approximately 10 - 15 minutes), and the Auger Light will continue to flash to the corresponding Heat Level setting.

To OPERATE: Press the Heat Level button to change the desired Heat Level Output setting.

The speed of the convection blower is controlled by the setting of the heat level. This blower can be turned OFF by depressing the convection blower control button. For the best efficiency, the convection blower should be left on at all times.

When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel). Or if the

low setting is too hot for the room (see “OPERATING INSTRUCTIONS; CONTROL BOARD FUNCTIONS”).

HIGH/LOW MODE: (Requires a Thermostat or Timer)

INITIAL START-UP: See MANUAL MODE above.

OPERATION: When the thermostat calls for heat (contacts are closed) the stove settings are adjustable as per Manual Mode. When the thermostat contacts open, the HEAT LEVEL and Fans will drop down to the LOW setting until the thermostat contacts close again. *The LOW heat setting can be adjusted for different fuel qualities

(see “OPERATING INSTRUCTIONS - CONTROL BOARD FUNCTIONS”). The stove will

come back to the previous HEAT LEVEL setting when the thermostat contacts close again.

AUTO/OFF MODE: (Requires a Thermostat or Timer)

INITIAL START-UP: See MANUAL MODE above.

OPERATION: When the thermostat contacts close, the unit will light automatically. Once up to temperature, the stove operates the same as







 

 

Figure 4: Thermostat Switch in

HIGH/LOW position.







 

 

Figure 5: Thermostat Switch in

AUTO/OFF position.

8

Page 8
Image 8
Enviro 50-1573 owner manual Manual Mode

50-1573 specifications

The Enviro 50-1573 is an innovative and eco-friendly solution aimed at addressing the growing needs of businesses and consumers alike. This product is designed with a focus on sustainability without compromising on performance or functionality.

One of the most notable features of the Enviro 50-1573 is its advanced energy efficiency technology. It uses state-of-the-art mechanisms to minimize energy consumption, making it an ideal choice for environmentally conscious users. Its design incorporates high-efficiency components that significantly reduce the carbon footprint while still delivering optimal performance. This efficiency not only helps the environment but also results in cost savings for users.

The Enviro 50-1573 is built using sustainable materials, which is a crucial characteristic for modern consumers. The use of recycled and non-toxic materials ensures that the product is safe for both the user and the planet. Manufacturers prioritize the lifecycle impact of their products, ensuring that they are designed to be recyclable or biodegradable at the end of their use.

In terms of technology, the Enviro 50-1573 incorporates smart features that enhance user experience. It includes an intuitive control system that allows users to monitor performance and make adjustments easily. This technology can be further integrated with mobile applications, allowing for remote operation and real-time tracking of energy usage and efficiency metrics.

Safety is another key characteristic of the Enviro 50-1573. It is designed with multiple safety protocols to protect users and surrounding environments, ensuring peace of mind during operation. These protocols include overload protection and automatic shut-off features, which help to prevent accidents and energy waste.

Moreover, the Enviro 50-1573 offers versatility, as it can be used in a variety of settings, from residential to commercial applications. Its streamlined design allows it to fit seamlessly into any environment without being obtrusive.

In conclusion, the Enviro 50-1573 stands out in the market for its commitment to sustainability, energy efficiency, and user-friendly technology. By prioritizing eco-friendliness alongside cutting-edge features, it meets the demands of today’s environmentally aware consumers while providing unwavering performance. Whether for home or business use, the Enviro 50-1573 represents a forward-thinking approach to products designed for a sustainable future.