OPERATING YOUR PELLET STOVE:

PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed correctly against the ignitor tube with the large vertical lip at the front for proper operation. Check the hopper for enough pellets to start the unit.

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.

MANUAL MODE:

To START: Press the ON / OFF button. The stove will turn on, it may take fifteen (15) seconds for the lights on the control board to come on. The Auger Light will flash with each pulse of the auger (the Auger Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that the stove will run at after start-up and can now be set.

If this is the first time the unit has been started or the unit has run out of fuel, a handful of pellet should be placed in the burn pot.

To OPERATE: When a fire has been established (after approximately 10 - 15 minutes) and the Auger Light will start to flash to the corresponding Heat Level setting. The Heat Level will now be at the desired Heat Level Output setting.

The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting of the heat level output indicator.

When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different quality fuels. These settings can be used if the fire keeps going out on low (for poor quality fuel) or if the low setting is too hot for the room. This button is on the Motherboard behind the surround panel.

THERMOSTAT / SWITCH MODE:

INITIAL START-UP: See above

OPERATION - HI / LOW mode: When the thermostat contacts are closed the stove settings are adjustable as per Manual Mode (see above). When the thermostat contacts open, the circuit board will take control of the settings. The stove will drop down to a low burn until the thermostat contacts close again. This low burn setting can be adjusted for different fuel qualities. The stove will come back to the previous HEAT LEVEL setting when the thermostat contacts close again.

OPERATION – ON / OFF mode: When the thermostat contacts close, the unit will light automatically. Once up to temperature, the stove operates the same as in manual mode (see above). When the thermostat contacts open, the unit automatically begins its shutdown routine. The stove will re-light when the thermostat contacts close again.

TURNING YOUR PELLET STOVE OFF:

MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough, the stove will turn off.

ON / OFF mode: To turn the unit OFF, turn the thermostat down or off.

DO NOT unplug unit while Combustion fan is operating.

This will lead to smoke escaping from the stove.

8

Page 8
Image 8
Enviro C-11114, C-10808, 50-1385 owner manual Thermostat / Switch Mode, Initial START-UP See above

C-10808, C-11114, 50-1385 specifications

Enviro 50-1385, C-11114, and C-10808 are innovative formulations designed for various applications in the field of environmental engineering and industrial processes. Each of these formulations boasts unique main features, technologies, and characteristics that contribute to their efficacy and versatility.

Enviro 50-1385 is a cutting-edge product known for its exceptional biodegradability and low toxicity. It effectively addresses waste management and pollution reduction in industrial settings. This formulation is characterized by its ability to degrade organic compounds efficiently, making it ideal for use in wastewater treatment facilities. The advanced microbial technology incorporated in Enviro 50-1385 enhances its performance, ensuring that harmful pollutants are broken down, thus reducing environmental impact. Additionally, its formulation is designed to work effectively across a wide range of pH levels and temperatures, providing reliable performance in diverse conditions.

C-11114 stands out for its robust chemical composition, making it suitable for heavy-duty industrial cleaning and degreasing applications. This formulation features a blend of surfactants and solvents that provide powerful cleaning action while remaining environmentally friendly. The unique surfactant technology in C-11114 allows it to penetrate and lift grease and oils quickly, making it an ideal choice for manufacturers seeking effective cleaning solutions without compromising on environmental safety. Its low VOC (volatile organic compounds) content further aligns with modern regulatory requirements, making it a responsible choice for businesses focusing on sustainability.

C-10808 is designed for use in environmentally sensitive areas, combining effectiveness with safety. This formulation features advanced encapsulation technology, which allows the active ingredients to maintain potency while minimizing direct exposure during application. C-10808 is especially effective in controlling odors and removing contaminants in air and water systems, making it an essential tool in environmental remediation projects. The user-friendly application method, combined with its fast-acting properties, makes C-10808 a preferred choice for field technicians and environmental engineers alike.

In summary, Enviro 50-1385, C-11114, and C-10808 offer distinct advantages for various industrial and environmental applications. With their innovative technologies and sustainable characteristics, these formulations represent a significant advancement in providing effective solutions while prioritizing environmental safety. Each product is thoughtfully developed to meet the evolving needs of industries committed to sustainability and responsible practices.