Initial Installation

QUALIFIED INSTALLERS ONLY

HORIZONTAL INSTALLATION:

STEP 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance.

STEP 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented towards the wall or floor, as much out of view as possible.

Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe (non-flared end). Place a bead of high temperature silicone on the male edge of the outer pipe. Push the pipe sections completely together, then twist-lock one section clockwise approximately 1⁄4 turn, until the two sections are fully locked. The female locking lugs will not be visible from the outside, on black

pipe. They may be located by examining the inside of the

 

female ends as shown in Figure 16.

 

 

 

10"

 

Notes:

 

 

(254mm)

 

 

 

 

 

(1) Twist-lock procedure:

 

 

four

(4)

indentations,

10"

 

located on the female end

(254mm)

 

 

Female

of the pipes and fittings, are

 

Locking

designed to

slide straight

 

Lugs

onto the male ends of

 

 

 

Sealant

adjacent pipes and fittings,

 

Male

by orienting

the

four pipe

 

indentations so they match

 

Locking

 

Lugs

and slide into the four entry

 

 

slots on the male end.

 

 

(2) Horizontal runs of vent

Figure 17: Wall Framing Hole for

 

pipe

must

be

supported

Figure 16: Twist-Lock Connection

Horizontal Installation.

 

 

 

 

11/4"

 

(3.2cm)

 

Fold strap

Woodscrews

 

here

 

Sheet metal

 

screws

 

 

Wall Thimble

 

Strap

Figure 18: Installing Decorative Wall Thimble.

17

Page 17
Image 17
Enviro C-10914 owner manual Pipes and fittings, are